This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued.
Solicitation number 1240BJ27Q0006 is issued as a Request for Quotation (RFQ) for the replacement of the HVAC system at the Tonasket Ranger Station. This will not be an HVAC replacement in-kind for the existing system. The replacement HVAC system shall be designed and installed based upon consideration of current energy standards. Work includes removal of existing HVAC equipment, delegated design, and installation of new HVAC equipment.
This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220 Plumbing, Heating, and Air-Conditioning Contractors The small business size standard is $19,000,000.00 This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.
Location: The Tonasket Ranger Station Office Building 2007 is located at street address: 1 W Winesap St, Tonasket, Washington 98855.
The contractor shall furnish all labor, supervision, tools, materials, equipment, incidental engineering, delegated design, transportation, and management necessary for the removal and replacement of the HVAC system. Work includes: delegated design (HVAC system assessment, load testing, system sizing with life cycle costing, and final mechanical/electrical plans sealed by a licensed HVAC Mechanical Engineer); removal of existing HVAC equipment and components; installation of new engineered HVAC system equipment (heat pumps, furnace, air handlers, fresh air units, air filtration systems, dampers, thermostats, and system controls); ductwork cleaning, repair, and modifications; electrical work (removal of existing feeders, upgrade of services/panels, and connections to new equipment); HVAC system testing and commissioning by an independent third party; provision of as-built AutoCAD drawings; and maintenance and operation training and manuals. The contractor must also repair any structural damage to truss components from the 1995 equipment installation. Option Item 2 requires an ESA inspection of other site HVAC equipment and replacement of two unit space heaters and a Haier air conditioner. Option Item 3 requires removal and replacement of the HVAC system at the Republic Ranger Station residence, including removal of an electric furnace, wood stoves, and fans, and installation of a new heat pump system, wood-burning fireplace insert, and chimney liner.
We post new hvac opportunities in Washington as agencies publish them. Get them in one email — free, and unsubscribe whenever.
"US""US""97601""KLAMATH FALLS""OR""USA""FREMONT WINEMA NF KLAMATH FALLS""2819 DAHLIA STREET""C04_1_RFQ_1240BJ27Q0006.pdf"1702544"file"".pdf""1""2026-11-04T20:06:43.586+00:00""b5416ffc8e04434f914effa034467458""public""0""public""26f14afdd85b4b82b9d8f7fe23cd43b2""0"21"0""C04_2_Attachment 1 SOW Appendices.pdf"36724684"file"".pdf""1""2026-11-04T20:06:43.586+00:00""3d07aed14dcb4ee99c8efcb044b01503""public""0""public""33e18bbe629a4c3c86d968e95ed87114""0"19"0""C04_2_Attachment 2 RS Floorplan HVAC Locate.pdf"1229490"file"".pdf""1""2026-11-04T20:06:43.586+00:00""2be7a2428d634a3bb9a8d3da61abe670""public""0""public""b58fac0e0e9249689298d60dd0a150c3""0"17"0""C04_2_Attachment 3 RS HVAC Specifications.pdf"3338482"file"".pdf""1""2026-11-04T20:06:43.586+00:00""208b1e62f7b24bc481e56508a1265d1a""public""0""public""c6d3f7dcd0364b3fbf33f6db6523ebb7""0"15"0""C04_2_Attachment 4 Construction Wage Determination.pdf"2097339"file"".pdf""1""2026-11-04T20:06:43.586+00:00""de1938a4487a4ce583912f07cf2e369e""public""2026-11-05T17:25:26.494+00:00""1""public""2927895ec0a4475ea7f72f2297704367""0"11"0""2026-11-05T17:25:26.494+00:00""C04_2_Attachment 4 Construction Wage Determination.pdf"2186495"file"".pdf""1""2026-11-05T17:25:26.494+00:00""0b9211e9f3354b768b112afcacc1507c""public""0""public""6cc9cb2443db49b3a01c46528ed65845""0"5"0""C04_3_Quote Template.docx"49888"file"".docx""1""2026-11-04T20:06:43.586+00:00""568729437d7d4c6d8ac36ea06931c12a""public""0""public""7f0c75b32a4048cfaa6defe90b77fdba""0"4"0""C04_4_BidBondSF24.pdf"720305"file"".pdf""1""2026-11-04T20:06:43.586+00:00""06c8087838b2433fa25ee72aae1689df""public""0""public""a8920a8bef0a4b79802d7e41602723b3""0"3"0"Read from this solicitation’s own documents — each row shows the exact quote it was matched to. Confirm final amounts and forms with the issuing agency before you submit.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what a GC or agency asks to see before they take your bid seriously.
Source: SAM.gov (notice 437677f94aab4f34a7733c8d9b90ec46), retrieved via the SAM.gov Get Opportunities API. View the official posting, and always confirm requirements and deadlines with the issuing agency.