COMBINED SYNOPSIS/SOLICITATIONÂ
GENERAL INFORMATIONÂ
Â
Document Type:Â
Combined Solicitation/SynopsisÂ
Solicitation Number:Â
36C26227Q0112
Posted Date:Â
11/20/2026
Product of Service Code:
NAICS Code:Â
811310
Contracting Office AddressÂ
NCO 22Â
ATTN: Chase SullivanÂ
Department of Veterans AffairsÂ
3601 S. 6Th Avenue
Building 45Â
Tucson, AZ 85723
Â
DescriptionÂ
This is a combined synopsis/solicitation is for services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation document will not be issued.Â
Â
This solicitation is a request for quotations (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 / 03/13/2026.Â
Â
The associated North American Industrial Classification System (NAICS) code for this procurement is 811310, with a small business size standard of $12.5 Million Dollars. NAICS code must listed in the vendor profile on SAM.gov, Reps and Certs (FAR/DFARS), scroll to FAR 52.219-1. Complete the self-certification.
Â
The Network Contracting Office 7 is seeking Essential Electrical System (EES) Switch Gear Testing for the San Diego VA Medical Center located in San Diego, CA
Â
All questions regarding this RFQ must be in writing and may be sent by e mail to chase.sullivan@va.gov and NCO22SERVICES4SOLICITATIONINBOX@va.gov Questions must be received no later than November 27, 2026, at 12AM PST (PST). No further questions will be accepted after that date and time.Â
Â
All offers must be in writing and may be sent by e mail to chase.sullivan@va.gov and NCO22SERVICES4SOLICITATIONINBOX@va.gov. Offers must be received no later than December 4, 2026, at 12PM PST (PST). No further offers will be accepted after that date and time.Â
You are reminded that representatives from your company SHALL NOT contact any VA Medical Center employees to discuss this RFQ during this RFQ process. All questions and concerns regarding this RFQ shall be directed to the Contracting Officer.Â
Â
SCHEDULE:Â VA San Diego Healthcare System (VASDHS) currently has a requirement for Essential Electrical System (EES) Switch Gear Testing is needed for various multiple buildings throughout the campus.
See the Statement of Work within the RFQ for further details.
The contractor must provide maintenance and testing of the electrical distribution system at VA San Diego Medical Center for specified buildings, including Medium Voltage Switches, circuit breakers, protective relays, transformers, switchboards, and automatic transfer switches. Work includes performing electrical preventive maintenance on Primary Electrical Substations Systems, conducting NETA standard testing, thermographic surveys, oil sampling, and providing a comprehensive engineering report on testing data and findings. The contractor must furnish all field service personnel, tools, materials, and approved test equipment. Testing will be performed per NETA standards by personnel certified by NICET. The contractor is also responsible for safety training, complying with OSHA and NFPA standards, and providing and installing safety locks and grounds.
We post new equipment maintenance & rental opportunities in California as agencies publish them. Get them in one email — free, and unsubscribe whenever.
"US""90815""LONG BEACH""CA""USA""4811 AIRPORT PLAZA DRIVE""SUITE 600""W-9 Form 1.pdf"255432"file"".pdf""1""2026-11-20T22:19:27.159+00:00""bdd4143b5339469fa243f2e24388c960""public""0""public""15b509fb412b4863b4f6314569f4b91e""0"5"0""FMS Vendor File Update Request Form.pdf"276600"file"".pdf""1""2026-11-20T22:19:27.159+00:00""488c17d6fb4f436a9e142c551045f8c9""public""0""public""8aa8748da0d04cd683e237709be01f04""0"4"0""VA10091 1.pdf"92006"file"".pdf""1""2026-11-20T22:19:27.159+00:00""f4969d6ad6b248dbb567e8ffcc3b3eeb""public""0""public""1cf87ec4b4d34d38842f1e666ee09197""0"3"0""S02 - 36C26227Q0112_1 - ESS Testing.pdf"497260"file"".pdf""1""2026-11-20T22:19:27.159+00:00""e5cb58c7b4bd4d9aa5c8733a2d76525c""public""0""public""31c4ab1fcb124e2598b2c05c8a0e1db9""0"2"0""36C26227Q0112_3.docx"17421"file"".docx""1""2026-11-20T22:19:27.159+00:00""6545e01a4900448e8d5f4f5f0668edb4""public""0""public""dda899e8db684f4a877ef920aa3e9264""0"1"0"Most California work asks for the two below, and the solicitation documents are where it’s stated. One prequalification covers both — on this bid and the next.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what an agency asks to see before they take your bid seriously.
Source: SAM.gov (notice d4237287f7db418cb0fe8bab82712d02), retrieved via the SAM.gov Get Opportunities API. View the official posting, and always confirm requirements and deadlines with the issuing agency.