Replace Boilers 4 and 5
CON
Contractor shall furnish all labor, materials, equipment and supervision to demolish existing boilers, controls, electronics and electro-mechanical infrastructure in Building 112, install a single new 600 HP firetube Boiler #5 with economizer, steam header, feedwater, condensate, fuel oil, natural gas, compressed air, chemical feed and vent piping, electrical distribution, lighting, lightning protection, architectural wall, roof and coiling door work, civil concrete pad and fencing, startup, commissioning, training and O&M manuals, with Bid Alternate Item 1 retaining Boiler #4.
We post new hvac opportunities in Wisconsin as agencies publish them. Get them in one email — free, and unsubscribe whenever.
"US""53214""MILWAUKEE""WI""USA""GREAT LAKES ACQUISITION CENTER""115 S 84TH ST""A0003 - VA 695-24-107 Addendum 03 Combined Drawing SetPart-1.pdf"6253117"file"".pdf""1""2026-11-19T20:05:52.703+00:00""1e2b3f95684f46d9857b391cdfc12854""public""0""public""5d0696b62098431eb4028f576b4d4364""0"24"0""A0003 - VA 695-24-107 Addendum 02 Combined Specifications (1).pdf"3280259"file"".pdf""1""2026-11-19T20:05:52.703+00:00""355ea8ca349f4503a8a468501a2d3a22""public""0""public""d0c8fcf149614aae90f900a7a9404e12""0"23"0""A0003 - PIV procedure for KTRs.pdf"768963"file"".pdf""1""2026-11-19T20:05:52.703+00:00""fe1dfbe3ee7846fe8fdcc67da3b54908""public""0""public""5b2b48ffe34b4a1ba5d201c33cd59993""0"22"0""A0003 - VA 695-24-107 Addendum 03 Combined Drawing SetPart-2.pdf"6250681"file"".pdf""1""2026-11-19T20:05:52.703+00:00""ec633ccb08f543b9a7599164b9414c80""public""0""public""7a9430804c7c4067ab02d14ba7066aa6""0"21"0""A0003 - VA 695-24-107 Addendum 03 Combined Drawing SetPart-3.pdf"6087452"file"".pdf""1""2026-11-19T20:05:52.703+00:00""070ec2f47e8b4373a58662fc7fdfbed0""public""0""public""3da9fc58d3684fc6ab28b5927d7918e6""0"20"0""A0003 - 695-22-106 Bldg 112 Lightning Protection PLAN.pdf"426593"file"".pdf""1""2026-11-19T20:05:52.703+00:00""a274d1d43b114049be0633bc3dce9f85""public""0""public""2eb975ab603e4cd4b48f0b48ca562063""0"19"0""A0003 - Blr 4-5 nameplates.pdf"305779"file"".pdf""1""2026-11-19T20:05:52.703+00:00""1a75803da2b544d5ab6179b72d3d07a6""public""0""public""208add82fb1d44dbb90efbdbd08fa862""0"18"0""A0003 - PAGE 11 UPDATED.pdf"40322"file"".pdf""1""2026-11-19T20:05:52.703+00:00""d7d6eb14c3bf444f81b44211926fb477""public""0""public""b1f08e52a28143afa7fe424e9e21ea28""0"17"0""36C25227B0001 0003.docx"213992"file"".docx""1""2026-11-19T20:05:52.703+00:00""e648abe5629e4804bb3fee94c2d2b9c4""public""0""public""6b20993278784cf99fca39fc9f0b9228""0"17"0""S06 - 36C25227B0001 0002.pdf"207206"file"".pdf""1""2026-11-12T14:15:52.737+00:00""69d27a9cac554aaeae3b21ddeaca404c""public""0""public""8f859694d2254245b748f4e5869a3d37""0"16"0""S06 - site visit sign in 10-14-26.pdf"1212825"file"".pdf""1""2026-10-19T18:07:18.738+00:00""298dd2d5098b44568dee4d1a94db5a43""public""0""public""4ca580fbcc0f45e7963c6c7d9cb7e5e0""0"15"0""36C25227B0001 0001.docx"122689"file"".docx""1""2026-10-19T18:07:18.738+00:00""016004bb893344b89a403035e09b20ea""public""0""public""93bcd620a23d4cd5b1c38b496af03951""0"14"0""SOLICITATION-DESCRIPTION.docx"280069"file"".docx""1""2026-10-06T18:58:16.099+00:00""7e3fa9e2ab72463a8c3907dd90c95914""public""0""public""12b6d900b786405ca1b4e5117f09a896""0"13"0""S02 - ATT A - Drawing Set Part-1.pdf"12303814"file"".pdf""1""2026-10-06T18:58:16.099+00:00""7df353606a18467981759bb6a1d2251c""public""0""public""3f1bc340d4a5496d969429a80ee2a07f""0"12"0""S02 - ATT B- Drawing Set Part-2 (1).pdf"11250422"file"".pdf""1""2026-10-06T18:58:16.099+00:00""5c4b4f95f94d453fbaf2c141d2872332""public""0""public""b1c901b4c5864d38bc2b0592a82a903c""0"10"0""S02 - ATT F - MAP.pdf"5425529"file"".pdf""1""2026-10-06T18:58:16.099+00:00""9d466c5610a54e928ae0eb5dcb40b837""public""0""public""bc777ecc9e83469c8c6fe91a0af25b0c""0"8"0""S02 - ATT C - Specifications.pdf"5205768"file"".pdf""1""2026-10-06T18:58:16.099+00:00""ff3b34790f604263a063530ae84181ad""public""0""public""f5fe280a39a3430a92c4ffb5992f6c23""0"6"0""S02 - ATT G - Wage Determination.pdf"328277"file"".pdf""1""2026-10-06T18:58:16.099+00:00""3255d21cee994b9f8e15f97615b29539""public""0""public""7d8208d601f44af086b26116575bdb76""0"4"0""S02 - ATT D - JnA Boiler Controls.FE.pdf"232763"file"".pdf""1""2026-10-06T18:58:16.099+00:00""66be113f05754ecfb2e2b34ee07f22ed""public""0""public""d731d5fcb39a4493a35ea0f5e2147d54""0"2"0""S02 - ATT E - VAAR 852.219-75_REQUIRED.pdf"136613"file"".pdf""1""2026-10-06T18:58:16.099+00:00""d7b39a1e2153410c8cd7e3a81038e7f6""public""0""public""4e763dc7b85f4e5ead7907432baeb4a1""0"1"0"Read from this solicitation’s own documents — each row shows the exact quote it was matched to. Confirm final amounts and forms with the issuing agency before you submit.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what a GC or agency asks to see before they take your bid seriously.
Source: SAM.gov (notice a9bc8001b31046a8ad4d6a8db7cfec2c), retrieved via the SAM.gov Get Opportunities API. View the official posting, and always confirm requirements and deadlines with the issuing agency.