The City of HoustonAirport System is seeking a qualified vendor to furnish and deliver one (1) pair of commercial-grade, 16-gauge steel doors and associated parts/hardware in accordance with the specifications and quantities listed below. Bidders shall submit a complete quotation addressing all requirements of this solicitation.
The vendor shall provide all required materials, hardware, factory preparations, and delivery necessary to furnish a complete and functional pair of doors.
Door Specifications
Quantity: One (1) pair / two (2) door leaves
Door Size: 3'-0" W × 7'-0" H per door leaf
Overall Pair Opening: Approximately 6'-0" W × 7'-0" H
Material: 16-gauge steel
Door Type: Commercial hollow metal double-door assembly
Finish: Factory-applied prime-painted finish suitable for field painting
Lock Preparation: ANSI 161 cylindrical lock preparation
Flush Bolt Preparation: Factory preparation for flush bolts
Handing: To be specified and confirmed by the city prior to fabrication
Frame/Throat: 4-inch nominal frame/header or applicable frame throat depth consistent with the existing installation
Hardware Requirements
Continuous Hinge: One (1) Roton 780-053 continuous hinge.
Flush Bolts: Two (2) 1555 flush bolts in 26D finish.
Thresholds: Two (2) Hager 541V, 72-inch aluminum thresholds.
Weatherstrip: One (1) complete set, 6070 / 891-6070.
Meeting Astragals: One (1) set of Hager 756V, 7-foot meeting astragals.
Hinge Fillers: Six (6) H45 hinge fillers.
Door Closers: Two (2) Norton 7500 door closers, 689 finish.
Astragal/Flush Bolt Component: One (1) ASA FB Astrical installed, with handing as required by the door configuration.
The vendor shall provide all required materials, hardware, factory preparations, and delivery necessary to furnish a complete and functional pair of doors. The doors are 3'-0" W × 7'-0" H per leaf, 16-gauge steel, commercial hollow metal double-door assembly, with factory-applied prime-painted finish, ANSI 161 cylindrical lock preparation, and factory preparation for flush bolts. Required hardware includes one Roton 780-053 continuous hinge, two 1555 flush bolts in 26D finish, two Hager 541V 72-inch aluminum thresholds, one complete set of 6070/891-6070 weatherstrip, one set of Hager 756V 7-foot meeting astragals, six H45 hinge fillers, two Norton 7500 door closers in 689 finish, and one ASA FB Astrical installed.
We post new interior installation opportunities in Texas as agencies publish them. Get them in one email — free, and unsubscribe whenever.
{"type":"document-upload","prompt":"Please upload your completed Signature Page. ","required":true,"attachments":[{"key":"agency/281287c2-49c0-439e-81d7-315d13b0b4fb/form-attachment/1738095531177_8e091c0a-993a-48bf-9d87-e62f06d24d6d/InformalSignaturePage.docx","name":"Informal Signature Page.docx","type":"application/vnd.openxmlformats-officedocument.wordprocessingml.document","bytes":18871,"bucket":"documents.beaconbid.com","createdAt":"2026-10-07T17:18:00.639Z"}]}{"id":"15bd4426-2f24-4019-8c23-9e64c64135e5","name":"PR DR 3070/4 161/MB FB PREP HAND PM/16GA","notes":"","details":"","quantity":"1","quantityType":"each"}{"id":"2a14a367-bd8d-4bd7-a96a-1a3467cbb810","name":"ASA FB ASTRICAL INSTALLED HAND","notes":"","details":"","quantity":"1","quantityType":"each"}{"id":"fcf0f1f4-2c99-4ff2-a453-58da58a09305","name":"CONTINIOUS HINGES 780-053 ROTON","notes":"","details":"","quantity":"2","quantityType":"each"}{"id":"8e0ce1af-be6a-442b-a7cf-444b3e4c1975","name":"FLUSH BOLTS 1555 26D","notes":"","details":"","quantity":"2","quantityType":"each"}{"id":"750fb321-967c-4519-9104-fcab87a65eb8","name":"THRESHOLD HAGER 541V 72\" ALUM","notes":"","details":"","quantity":"1","quantityType":"each"}{"id":"bb139cd8-6f9e-48c1-ad3a-6031b96ca421","name":"SET OF WEATHERSTRIP 6070 891-6070","notes":"","details":"","quantity":"1","quantityType":"each"}{"id":"225fd245-2c7e-48ac-a11e-cb82a2bf883b","name":"SET OF MEETING ASTRAGALS HAGER 756V 7FT","notes":"","details":"","quantity":"1","quantityType":"each"}{"id":"afe831a1-b13f-46cb-99b0-b8f0f6e56f99","name":"HINGE FILLERS H45","notes":"","details":"","quantity":"6","quantityType":"each"}{"id":"25f6c6ee-29a6-454b-b4c4-0d119e73179d","name":"NORTON 7500 CLOSERS 689 FINISH PA","notes":"","details":"","quantity":"2","quantityType":"each"}{"id":"3642b888-9b74-4b23-9723-6b2c9fb83e29","name":"FREIGHT","notes":"","details":"","quantity":"1","quantityType":"each"}{"colId":"name"}{"colId":"details","hidden":true}{"colId":"quantity"}{"colId":"quantityType"}{"colId":"notes"}{"colId":"estimatedValue","hidden":true}{"colId":"response.unitPrice"}{"colId":"response.markupPercent","hidden":true}{"colId":"response.notes"}{"colId":"response.nobid"}{"type":"document-upload","prompt":"Please upload your official quote on company letterhead.","required":true,"attachments":[]}Most Texas work asks for the two below, and the solicitation documents are where it’s stated. One prequalification covers both — on this bid and the next.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what a GC or agency asks to see before they take your bid seriously.
Source: City of Houston (solicitation 905567e6-27be-4f4f-8129-3509f652d0c9), retrieved via the City of Houston BeaconBid portal. View the official posting, and always confirm requirements and deadlines with the issuing agency.