General Services Administration (GSA) seeks to lease the following space:
State: Washington
City: Sumner
Delineated Area:
North: WA-16, Pearl, 30th St, Schuster Pkwy, 1-705, WA-509, WA-99, 304th St, Military Rd S, WA-18, WA-167, 15th St NW, Harvey Rd, 8th St, Lea Hill Rd, 312th St, 312th St Way, WA-18, Auburn-Black Diamond Rd, Roberts Dr.
South: 224th St
East: WA-169, WA-164, WA-410, WA-165, WA-162, Kansas St, Calistoga St, Orting Kapowsin Hwy.
West: Burlington Northern Railroad, I-5, Tacoma Way, 112th St, Steele St, 116th St, Spanaway Loop Rd, 176th St, WA-7.
Min Square Feet (ABOA): 441,250
Max. Square Feet (ABOA): 442,000
Space Type: Warehouse, Office, Light Industrial and Wareyard
Parking Spaces (Total): 324
Parking Spaces (Surface): 324
Parking Spaces (Structured): 0
Parking Spaces (Reserved): 324
Full Term: 10 Years
Firm Term: 10 Years
Additional Requirements:
30' minimum clear height.
50’ minimum column spacing.
10 loading docks with dock doors, each sized 10’ X 9’, equipped with hydraulic loading dock levers with a vehicle restraint system. 5 receiving and 5 shipping, all with trailer hooks.
The site requires secure perimeter fencing and gates to the wareyard and parking per code.
Minimum two 18’(tall) x 141/2’(wide) roll up doors (yard access).
Specialized rooms, including:
Dyno and Hazmat room with specific HVAC and electrical requirements (hazardous materials anticipated include petroleum, paints, and thinners consistent with a vehicle maintenance/manufacturing facility).
Vetronics Clean Room: Minimum 31.9’ x 42.2’ with HEPA filtration system, and Anti-static floor.
Adjacency requirement: no shared buildings with non-DOD agencies due to security requirements.
Wareyard requirement:
Accommodate 50-foot tractor trailer storage containers.
Minimum size of 247,000 square feet.
Vehicle and logistics intake:
Must accommodate tractor trailers ranging from 20 feet to 70 feet (with trailer attached).
Turning radius must support full tractor trailer movement or include a passthrough drive for docking.
Warehouse must be able to accommodate:
Vertical retrieval system (VRS) units (in addition to 25-foot rack system).
Radio frequency (RF) line for RF guided Turret trucks.
Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease. A fully serviced lease is required. Offered space shall not be in the 1-percent-annual chance floodplain (formerly referred to as “100-year” floodplain).
Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR). For more information, visit: https://acquisition.gov/FAR-Case-2019-009/889_Part_B*.*
Send Offers to:
Name: Dan McGrath and Nicholas Zabelin
Broker Contractor - Carpenter/Robbins Commercial Real Estate Inc.
2000 Crow Canyon Place, Suite 130
San Ramon, CA 94583
Email Address: Daniel.J.Mcgrath@gsa.gov and Nicholas.Zabelin@gsa.gov
**Solicitation (RLP) Number: **4WA0688
Government Contact Information (Not for Offer Submission)
Darrin Hotaling - Lease Contracting Officer
Phone: (303) 963-6576
Email: Darrin.Hotaling@gsa.gov
Dan McGrath, GSA Broker Contractor - Carpenter/Robbins Commercial Real Estate, Inc.
Phone: (619) 840-7842
Email: Daniel.J.Mcgrath@gsa.gov
Nicholas Zabelin, GSA Broker Contractor - Carpenter/Robbins Commercial Real Estate, Inc.
Phone: (925) 790-2124
Email: Nicholas.Zabelin@gsa.gov
Note: Entities not currently registered in the System for Award Management (SAM.gov) are advised to start the registration process as soon as possible.
The Government requires a minimum of 441,250 to a maximum of 442,000 ABOA square feet of contiguous space on a single floor in a warehouse type building. The space must have a 30' minimum clear height, 50' minimum column spacing, 10 loading docks with dock doors (5 receiving, 5 shipping), a 247,000 square foot secured wareyard, and specialized rooms including a Dyno and Hazmat room and a Vetronics Clean Room. The site requires secure perimeter fencing, minimum two 18'x14.5' roll-up doors, and must accommodate tractor trailers up to 70 feet. The lease is for a 10-year firm term and is a fully serviced lease.
We post new vehicles & fleet opportunities in Washington as agencies publish them. Get them in one email — free, and unsubscribe whenever.
"US""20405""WASHINGTON""DC""USA""PBS R00 CENTER FOR BROKER SERVICES""1800 F STS NW""Request for Lease Proposals (RLP)_2026.9.10.pdf"355020"file"".pdf""1""2026-10-14T18:05:06.486+00:00""b2b1d32be23e4a35a34fa80ab4bde7e1""public""0""public""0267856d50b54c9fb8411da20df83206""0"58"0""Exhibit A Lease Template_2026.9.10.pdf"603157"file"".pdf""1""2026-10-14T18:05:06.486+00:00""483d623cb8434cfe942903f16f6e374c""public""0""public""c144eb259ee3426a89d2cfaa3df072bc""0"57"0""Exhibit B_3516 Solicitation Provisions (Mar. 2026).pdf"162267"file"".pdf""1""2026-10-14T18:05:06.486+00:00""771018151f4345da9d8e1c0da7bf37ed""public""0""public""08b8d637f7724bea8ceb5a12d9040372""0"55"0""Exhibit C_Sensitive Document Request.pdf"88330"file"".pdf""1""2026-10-14T18:05:06.486+00:00""61d7fe73f05b4585b6b7f68ae223bb71""public""0""public""9bd93b55b2f440749ae829b7afb74fec""0"53"0""Exhibit D Security Requirements for Level III.pdf"223711"file"".pdf""1""2026-10-14T18:05:06.486+00:00""b8174fde09bd491ea7516c3ab3845aea""public""0""public""d7bcfde120dd4f05a801a3c496df2e75""0"51"0""Exhibit E_3517B General Clauses (Apr. 2026).pdf"360205"file"".pdf""1""2026-10-14T18:05:06.486+00:00""4531a0eca72743bb904d7ad3453a10d0""public""0""public""ccb3b79b3b3b41aeac0ea9477d57551a""0"47"0""Exhibit F_Form 1364WH Proposal to Lease Space (Feb. 2026).pdf"837222"file"".pdf""1""2026-10-14T18:05:06.486+00:00""6190ba9df06b42ccacb2df2e67c5992b""public""0""public""d28c625d810042e384d24762c7476680""0"45"0""Exhibit G_GSA Form 1217 (Nov. 2016).pdf"1319566"file"".pdf""1""2026-10-14T18:05:06.486+00:00""da8e3ad74bba4ebb8beaafb5a9d456b4""public""0""public""c0ca536985af474eabd6f3deaf3aa351""0"42"0""Exhibit H_Form 12000WH Prelease FPLS Evaluation (May.2024).pdf"273696"file"".pdf""1""2026-10-14T18:05:06.486+00:00""a49e407b6bb545a1ab41d2ab7fcf2826""public""0""public""c99707fa46ed493582a43dee4af31045""0"35"0""Exhibit I_Seismic Forms A - F with Instructions.pdf"213233"file"".pdf""1""2026-10-14T18:05:06.486+00:00""ade8b86b0e0b4dfe8409f5de31cc665b""public""0""public""069e3a86d5324ffe8061f2361b8a3fc3""0"29"0""Exhibit J_GSAR Representation 552.270-33 (Nov. 2024).pdf"183775"file"".pdf""1""2026-10-14T18:05:06.486+00:00""054e79860ac24a52b4bd97e17bb3c7d1""public""0""public""565b2154a8734604b0d7cba946c0fe35""0"21"0""Exhibit K_ RLP - Broker Project (May 2026).pdf"102535"file"".pdf""1""2026-10-14T18:05:06.486+00:00""2993b1c4340c44b0a2afd0f98c4d43b7""public""0""public""79763d5820264b788e7dda6acaf56aff""0"13"0""Exhibit K1_Lease - Broker Project (May 2026).pdf"76487"file"".pdf""1""2026-10-14T18:05:06.486+00:00""8bcf60f8d8e9485d8cfc1d48adcd1556""public""0""public""f80aa917e5b740dcac1107208b2e64b3""0"10"0""Exhibit L_Lease - Prospectus (May 2026).pdf"78163"file"".pdf""1""2026-10-14T18:05:06.486+00:00""531c224549d94223acef6a0d1c7e3e76""public""0""public""66386a54d3e24e4eb8dec0bb651a7ad7""0"8"0""Exhibit M_ RLP - Prospectus (May 2026).pdf"74013"file"".pdf""1""2026-10-14T18:05:06.486+00:00""f8c84383984e484a92bf2392013abe4b""public""0""public""07c8751bf59f42d58611de871192f0aa""0"7"0"Most Washington work asks for the two below, and the solicitation documents are where it’s stated. One prequalification covers both — on this bid and the next.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what an agency asks to see before they take your bid seriously.
Source: SAM.gov (notice 53a099d5dee845e7980e8c560e5b8c79), retrieved via the SAM.gov Get Opportunities API. View the official posting, and always confirm requirements and deadlines with the issuing agency.