  • The Texas Military Department is seeking competitive sealed proposals from General Contractors to modernize the Texas Army National Guard Victoria Readiness Center in Victoria, Texas.
  • The estimated Base Cost of the project is $3,350,000.00 with Proposal Options estimated at $650,000.00.
  • Mandatory site visits are scheduled for June 16, 2026 at 1:00 PM CT and June 17, 2026 at 10:00 AM CT at 106 E Mockingbird Lane, Victoria, Texas 77904.
  • Proposals are due by 1:00 PM CT on July 28, 2026, at Camp Mabry, Building 37, Austin, Texas 78703.
  • The deadline for submission of questions is June 30, 2026 at 4:00 PM CT.
  • Requirement: Respondents shall submit a bid bond and associated Power of Attorney for the TMD in the sum of not less than 5% of the proposal base amount of the proposal.
  • Requirement: Contractor is required to tender to Owner, prior to commencing the Work, performance and payment bonds, as required by Tex. Gov’t Code, Ch. 2253.

AI-generated, verify all details against the official documents.

Description

Per TGC 2269 and 437.054, the Texas Military Department (TMD) is seeking competitive sealed proposals from General Contractors to modernize the Texas Army National Guard Victoria Readiness Center (RC) facility in Victoria,Texas. Work includes but is not limited to hazardous materials identification andremediation design; site modifications and improvements including paving, drainage, exterior lighting, signage, dumpster enclosure, and site security infrastructure; building envelope improvements; life safety, accessibility, and code compliance upgrades; plumbing, fire protection, HVAC, controls/BAS, electrical, lighting, IT/telecommunications, and electronic security infrastructure improvements; interior finish renovations; kitchen/breakroom and latrine/shower/locker upgrades; and related civil, structural, architectural, interiors, mechanical, electrical, plumbing, fire protection, and communications work. The estimated Base Cost of this project is $3,350,000.00 with Proposal Options estimated at $650,000.00. General Contractors must request via the group email FY26VictoriaRCMM@cfmo.mil.texas.gov the Drawings/Plans and Specifications electronically in digital format.

Vendors MUST attend one (1) of the two (2) MANDATORY site visits at 1:00 PM CT on Tuesday, June 16, 2026, OR 10:00 AM CT, Wednesday, June 17, 2026, at 106 E Mockingbird Lane, Victoria, Texas 77904. Failure to attend one of the two site visits will result in disqualification of the response.

Competitive Sealed Proposals for TMD26-CFMO-0044703 Victoria Readiness Center Major Maintenance STAR will be received by the TMD until 1:00 PM CT, Tuesday, June 28, 2026, at Camp Mabry, Building 37, Austin, Texas 78703.

Documents12
ESBD_518995_1779375433414_Attachment A&B - RFP Construction Victoria RC MM STAR.pdfNL
ESBD_518995_1779375843095_Attachment C - 2026 UGCs and Supplemental.pdfNL
ESBD_518995_1779376057560_Attachment D - TMD T&C's Revision 6.pdfNL
ESBD_518995_1779376106156_Attachment E - Contractors Questionnaire & Evaluation Criteria.pdfNL
ESBD_518995_1779376163827_Attachment F - HSP.pdfNL
ESBD_518995_1779376220967_Attachment G - Project Specifications.pdfNL
ESBD_518995_1779376254752_Attachment H - Project DrawingsPlans.pdfNL
ESBD_518995_1779376360499_Attachment I - Owner Contractor Agreement.pdfNL
ESBD_518995_1779376514927_Attachment J - Non-Collusion Affidavit.pdfNL
ESBD_518995_1780082537250_Addendum 1 - TMD26-CFMO-0044703 Victoria RC MM STAR - Att. E Questionnaire.pdfNL
ESBD_518995_1784131074280_Addendum 2 - Victoria RC MM STAR.pdfNL
ESBD_518995_1784581812002_Addendum 3 - Victoria RC MM STAR.pdfNL

Contact

Name
Markus Maxwell
Phone
(512) 782-6970
Address
Texas
Full source recordfrom Texas SmartBuy (ESBD)
Title
Victoria Readiness Center Major Maintenance STAR
Detail
User
466639
Title
Victoria Readiness Center Major Maintenance STAR
Value
4,000,000.00
Opt Out
Yes
Status
6
Created
5/21/2026 9:53 am
Addendum
<b>7/20/2026 4:08 pm:</b> July 20, 2026 - Addendum 3<br> <b>7/15/2026 10:56 am:</b> Addendum 2 - The purpose of this addendum is to provide: 1. Addendum 2 - Attachment A – Question & Answer Document, 18 Pages 2. Addendum 2 - Attachment B – General Clarifications, Specifications & Drawings Updates (Read Instructions Below) 3. Addendum 2 - Attachment C – Site Visit Sign-In Documents, 7 Pages 4. Addendum 2 - Attachment D – Wage Rates, 10 Pages 5. Addendum 2 – Attachment E – Texas Military Department Standard Terms and Conditions Revision 8, 29 Pages <br> <b>5/29/2026 2:23 pm:</b> The purpose of this addendum is to provide the complete Attachment E – Contractor’s Questionnaire and Evaluation Criteria for vendor use and reference.
Approved
Yes
Nigp Codes
90922-Building Construction, Non; 91438-Electrical; 91450-Heating, Ventilating And Air Conditioning (Hvac); 91468-Plumbing; 91473-Roofing And Siding; 92678-Remediation Services, Environmental (Including Rehabilitation Services Hazardous Waste And Mold Remediation);
Zones List
Zone
1
Internalid
1
Zone
2
Internalid
2
Zone
3
Internalid
3
Zone
4
Internalid
4
Zone
5
Internalid
5
Agency Name
Texas Military Department - 401
Internalid
518995
Opt Out Flag
Yes
Plan Repost
No
Status Name
Addendum Posted
Attachments
Id
518995
File Id
33117307
File URL
/core/media/media.nl?id=33117307&c=852252&h=Fc2Wtz7vLsnwfV-vs06Vg-rQhCfMmIssYevYuSrTCwuQDIXB&_xt=.pdf
File Name
ESBD_518995_1779375433414_Attachment A&B - RFP Construction Victoria RC MM STAR.pdf
File Description
RFP Attachments A&B Victoria RC MM STAR
Id
518995
File Id
33117408
File URL
/core/media/media.nl?id=33117408&c=852252&h=c8qOmhAxVk3yNrJkwiiTciv6J0WeDrwiKVxVAth83MGraJUb&_xt=.pdf
File Name
ESBD_518995_1779375843095_Attachment C - 2026 UGCs and Supplemental.pdf
File Description
Attachment C
Id
518995
File Id
33117410
File URL
/core/media/media.nl?id=33117410&c=852252&h=qS7Q6NOjSt39hKx6vzKr4Rx0guclyuMCyppOBkfaFbweJ-hv&_xt=.pdf
File Name
ESBD_518995_1779376057560_Attachment D - TMD T&C's Revision 6.pdf
File Description
Attachment D
Id
518995
File Id
33117411
File URL
/core/media/media.nl?id=33117411&c=852252&h=kU1ofxvq5phkbTo9SBxbw0YItazD42YrDtISQGjsoIBjzQl6&_xt=.pdf
File Name
ESBD_518995_1779376106156_Attachment E - Contractors Questionnaire & Evaluation Criteria.pdf
File Description
Attachment E
Id
518995
File Id
33117412
File URL
/core/media/media.nl?id=33117412&c=852252&h=l73nmJnJmJnPY6XhXsgte_EfACOMOFXqBh2AspEcmPbD_scx&_xt=.pdf
File Name
ESBD_518995_1779376163827_Attachment F - HSP.pdf
File Description
Attachment F
Id
518995
File Id
33117413
File URL
/core/media/media.nl?id=33117413&c=852252&h=OHpte0FG1qsR5L9VuMLqmWMA1hUhLbHoSexNK-8Qo-lmd5Rb&_xt=.pdf
File Name
ESBD_518995_1779376220967_Attachment G - Project Specifications.pdf
File Description
Attachment G
Id
518995
File Id
33117414
File URL
/core/media/media.nl?id=33117414&c=852252&h=IAacK6rflw6rEZgyLbZcOuXggh0mD-qKDcS2UN4KNI9BUdAY&_xt=.pdf
File Name
ESBD_518995_1779376254752_Attachment H - Project DrawingsPlans.pdf
File Description
Attachment H
Id
518995
File Id
33117415
File URL
/core/media/media.nl?id=33117415&c=852252&h=nm3qy3_DJ76l61uBWhZxinQjZ-zOgOY9Jzdww3NG3abh6zEr&_xt=.pdf
File Name
ESBD_518995_1779376360499_Attachment I - Owner Contractor Agreement.pdf
File Description
Attachment I
Id
518995
File Id
33117417
File URL
/core/media/media.nl?id=33117417&c=852252&h=ins8zK-3bKhmQ5sXf17srV6_S8hPO8mlxrLj-m3vJGkk6w5M&_xt=.pdf
File Name
ESBD_518995_1779376514927_Attachment J - Non-Collusion Affidavit.pdf
File Description
Attachment J
Id
518995
File Id
33156395
File URL
/core/media/media.nl?id=33156395&c=852252&h=jHIuUJmwF70HuE6B-r1Kx-5A_b8VMott4aHS6-HsKD2iQj5z&_xt=.pdf
File Name
ESBD_518995_1780082537250_Addendum 1 - TMD26-CFMO-0044703 Victoria RC MM STAR - Att. E Questionnaire.pdf
File Description
Addendum 1 - Attachment E - Contractor's Questionnaire and Evaluation Criteria
Id
518995
File Id
33444557
File URL
/core/media/media.nl?id=33444557&c=852252&h=pBb2C3q5siyS09qWAyixvMRDzNqc0CrGVuNL0VkRk0kx1Tlv&_xt=.pdf
File Name
ESBD_518995_1784131074280_Addendum 2 - Victoria RC MM STAR.pdf
File Description
Addendum 2 - Victoria RC MM STAR
Id
518995
File Id
33474388
File URL
/core/media/media.nl?id=33474388&c=852252&h=7OozRBHoby-vQrCwv9H4u-UyueQlRdQP-HB2fQ3eKGi0nAni&_xt=.pdf
File Name
ESBD_518995_1784581812002_Addendum 3 - Victoria RC MM STAR.pdf
File Description
Addendum 3 -Revised Attachment A & B
Contact Name
Markus Maxwell
Ctcd Cert Num
1900060203
Description
<p class="MsoNormal" style="margin-bottom: 0in; line-height: normal; background: white;" data-mce-style="margin-bottom: 0in; line-height: normal; background: white;"><span style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;">Per TGC 2269 and 437.054, the Texas Military Department (TMD) is seeking competitive sealed proposals from General Contractors to modernize the Texas Army National Guard Victoria Readiness Center (RC) facility in Victoria,Texas. Work includes but is not limited to hazardous materials identification andremediation design; site modifications and improvements including paving, drainage, exterior lighting, signage, dumpster enclosure, and site security infrastructure; building envelope improvements; life safety, accessibility, and code compliance upgrades; plumbing, fire protection, HVAC, controls/BAS, electrical, lighting, IT/telecommunications, and electronic security infrastructure improvements; interior finish renovations; kitchen/breakroom and latrine/shower/locker upgrades; and related civil, structural, architectural, interiors, mechanical, electrical, plumbing, fire protection, and communications work. The estimated Base Cost of this project is $3,350,000.00 with Proposal Options estimated at $650,000.00.</span><span style="font-size: 11.5pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.5pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;"> </span><span style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;">General Contractors must request via the group email <a href="mailto:FY26VictoriaRCMM@cfmo.mil.texas.gov" data-mce-href="mailto:FY26VictoriaRCMM@cfmo.mil.texas.gov">FY26VictoriaRCMM@cfmo.mil.texas.gov</a> the Drawings/Plans and Specifications electronically in digital format.&nbsp;</span></p><p class="MsoNormal" style="margin-bottom: 0in; line-height: normal; background: white;" data-mce-style="margin-bottom: 0in; line-height: normal; background: white;"><span style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;"><br style="mso-special-character: line-break;" data-mce-style="mso-special-character: line-break;"><!-- [if !supportLineBreakNewLine]--><br style="mso-special-character: line-break;" data-mce-style="mso-special-character: line-break;"><!--[endif]--></span></p><p class="MsoNormal" style="margin-bottom: 0in; line-height: normal; background: white;" data-mce-style="margin-bottom: 0in; line-height: normal; background: white;"><span style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;">Vendors MUST attend one (1) of the two (2) MANDATORY site visits at 1:00 PM CT on Tuesday, June 16, 2026, OR 10:00 AM CT, Wednesday, June 17, 2026, at 106 E Mockingbird Lane, Victoria, Texas 77904. Failure to attend one of the two site visits will result in disqualification of the response.</span></p><p class="MsoNormal" style="margin-bottom: 0in; line-height: normal; background: white;" data-mce-style="margin-bottom: 0in; line-height: normal; background: white;"><span style="font-size: 11.5pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.5pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;">&nbsp;</span></p><p class="MsoNormal" style="margin-bottom: 0in; line-height: normal; background: white;" data-mce-style="margin-bottom: 0in; line-height: normal; background: white;"><span style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;" data-mce-style="font-size: 11.0pt; font-family: 'Helvetica',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #4d5256; mso-font-kerning: 0pt; mso-ligatures: none;">Competitive Sealed Proposals for TMD26-CFMO-0044703 Victoria Readiness Center Major Maintenance STAR will be received by the TMD until 1:00 PM CT, Tuesday, June 28, 2026, at Camp Mabry, Building 37, Austin, Texas 78703.</span></p>
Posting Date
5/21/2026
Response Due
7/28/2026
User Follows
No
Agency Number
401
Contact Email
markus.maxwell.nfg@cfmo.mil.texas.gov
Last Modified
7/21/2026 1:02 pm
Response Time
1:00 PM
Contact Number
(512) 782-6970
Created From POD
No
Solicitation Id
TMD26-CFMO-0044703
State Agency Cert
2
Posting Requirement
3
Statutory Exemption
TGC 437.054
Highway District List
District
1
Internalid
1
District Name
Paris
District
2
Internalid
2
District Name
Fort Worth
District
3
Internalid
3
District Name
Wichita Falls
District
4
Internalid
4
District Name
Amarillo
District
5
Internalid
5
District Name
Lubbock
District
6
Internalid
6
District Name
Odessa
District
7
Internalid
7
District Name
San Angelo
District
8
Internalid
8
District Name
Abilene
District
9
Internalid
9
District Name
Waco
District
10
Internalid
10
District Name
Tyler
District
11
Internalid
11
District Name
Lufkin
District
12
Internalid
12
District Name
Houston
District
13
Internalid
13
District Name
Yoakum
District
14
Internalid
14
District Name
Austin
District
15
Internalid
15
District Name
San Antonio
District
16
Internalid
16
District Name
Corpus Christi
District
17
Internalid
17
District Name
Bryan
District
18
Internalid
18
District Name
Dallas
District
19
Internalid
19
District Name
Atlanta
District
20
Internalid
20
District Name
Beaumont
District
21
Internalid
21
District Name
Pharr
District
22
Internalid
22
District Name
Laredo
District
23
Internalid
23
District Name
Brownwood
District
24
Internalid
24
District Name
El Paso
District
25
Internalid
25
District Name
Childress
State Agency Cert Text
Dual CTCD/CTCM certification
Posting Requirement Text
21+ Days for Solicitation Notice
Listing
Title
Victoria Readiness Center Major Maintenance STAR
Status
6
Created
5/21/2026 9:53 am
Nigp Codes
90922-Building Construction, Non; 91438-Electrical; 91450-Heating, Ventilating And Air Conditioning (Hvac); 91468-Plumbing; 91473-Roofing And Siding; 92678-Remediation Services, Environmental (Including Rehabilitation Services Hazardous Waste And Mold Remediation);
Agency Name
Texas Military Department - 401
Internalid
518995
Status Name
Addendum Posted
Posting Date
5/21/2026
Response Due
7/28/2026
Agency Number
401
Last Modified
7/21/2026 1:02 pm
Response Time
1:00 PM
Solicitation Id
TMD26-CFMO-0044703
Enriched
Yes
Nigp Codes
90922-Building Construction, Non; 91438-Electrical; 91450-Heating, Ventilating And Air Conditioning (Hvac); 91468-Plumbing; 91473-Roofing And Siding; 92678-Remediation Services, Environmental (Including Rehabilitation Services Hazardous Waste And Mold Remediation);
Agency Name
Texas Military Department - 401
Status Name
Addendum Posted
Posting Date
5/21/2026
Response Due
7/28/2026
Response Time
1:00 PM
Categorized By
llm
Solicitation Id
TMD26-CFMO-0044703

Source: Texas SmartBuy (ESBD) (solicitation TX_SMARTBUY-TMD26-CFMO-0044703), retrieved via the Texas Comptroller Electronic State Business Daily. View the official posting — always confirm requirements and deadlines with the issuing agency.