DIELECTRIC & STRUCTURAL TESTING
Type: Request for Bids (RFB). Agency: Transportation - Office Of The Secretary. Documents: Final_RFB_605_2700000160_1_SO_FORM.PDF — Assembled pdf file for document [RFB,605,2700000160,1] - Solicitation Printer
The annual inspection shall consist of AC Dielectric Testing (69 KV AC test for 180 seconds on the upper boom, 50 KV AC test for 180 seconds on the lower boom insulator, 35 KV AC test for 60 seconds on individual basket liner, 21 KV breakdown test on insulating oil, and bonding together all components in the upper boom) and Structural Analysis Test Program (magnetic particle testing on critical welded areas and ultrasonic sound testing on critical structural components). Written verification of compliance is required.
We post new architecture and design opportunities in Kentucky as agencies publish them. Get them in one email — free, and unsubscribe whenever.
Most Kentucky work asks for the two below, and the solicitation documents are where it’s stated. One prequalification covers both — on this bid and the next.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what a GC or agency asks to see before they take your bid seriously.
Source: Transportation - Office Of The Secretary (solicitation RFB-605-2700000160-1), retrieved via a public procurement portal. View the official posting, and always confirm requirements and deadlines with the issuing agency.