CONTACT INFORMATION|4|N743.49|WVG|7176052147|benjamin.t.spangler.civ@us.navy.mil|ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19||||||||||||||||||||HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999)|1|See specification sections C and E.|INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2|||GENERAL INFORMATION-FOB-DESTINATION|1|B|WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material |N50286|TBD|133.2|N/A|N/A|N39040 - Certifications|N/A|N/A |SEE DD FORM 1423 |PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL BENJAMIN.T.SPANGLER.CIV@US.NAVY.MIL|NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1||EQUAL OPPORTUNITY (SEP 2016)|2|||WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year from date of delivery.|One year from date of delivery.|||||WARRANTY OF DATA--BASIC (MAR 2014)|2|||BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11||||||||||||NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (OCT 2020)(DEVIATION 2020-O0008)|1||ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (NOV 2023)|13||||||||||||||BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5||||||BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1||ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAY 2024)|13|333613|750||||||||||||NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X|This amendment is issued to update the quantity.\This amendment is issued to extend the closing date.\This amendment is issued to update the quantity and the closing date.\This amendment is issued to dissolve the small business set-aside and to extend the closing date to 25APR2025.\This amendment is issued to extend the closing date to 01APR2025.\1.DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg.2. Portsmouth NSY's DODAAC has changed from N00102 to N50286. Any reference toN00102 within this order should be updated to N50286.3. The following proposed delivery schedule applies:Submission of Certification Data CDRLs will be on or before 20 days prior to scheduled delivery.PRODUCTION RADIOGRAPHY (PR) 135 DAYS AFTER APPROVAL OF RSS APPROVAL OF PR30 DAYS AFTER RECEIPTWeld procedure and qual data 120 days adc Approval of weld procedures and qual data 60 days after receipt PNSY review/acceptance of Certification CDRLs 6 working days after receipt of Certification DD 1423 CDRLs.
Final delivery of material will be on or before 638 days after effective date of the resulting contract.4. Any contract awarded as a result of this solicitation will be "DO" rated order; "DO" rated order certified for national defense use under the Defense Priorities and Allocations System (DPAS).5. NAVSUP WSS Mechanicsburg will be considering past performance in the evaluation of offers in accordance with FAR 13.106(a)(2) and DFARS 252.213-7000.6.
If drawings are included in the solicitation, access needs to be requested on the individual solicitation page on Contracts Opportunities on the Government's beta.SAM website. After requesting access, send an email to the Primary POC listed on the solicitation.7. This order is issued pursuant to Emergency Acquisition Flexibilities (EAF).8.
This requirement requires access to classified drawings. These drawings are not required to submit a quote, however, in the event of an award, a facility clearance may be required in accordance with FAR 52.204-2.\1. SCOPE1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system.
The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vitalshipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material.2. APPLICABLE DOCUMENTS2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence.
Nothing in this contract/purchase order,however, must supersede applicable laws and regulations unless a specific exemption has been obtained.2.2 Identification of Classified Documents - This contract/purchase order requires the Contractor to have authorized access to classified documents in accordance with the attached Contract Security Classification Specification (DD Form 254). The classified documents and security level are: ;803-6404016 confidential;2.3 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions.2.3.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (ElectricContractor Data Submission) at: ht tps://register.nslc.navy.mil/.
This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specificationrevisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009,R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract.2.3.2 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made.2.3.3 "Document References" listed below must be obtained by the Contractor.
Ordering information is included as an attachment to this contract/purchase order.DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0001 | A|49998|0032647DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0001.A | A|49998|0041250DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0002 | A|49998|0018549DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0003 | A|49998|0020330DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0004 | A|49998|0034988DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0004.A | A|49998|0014187DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0005 | A|49998|0053007DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0006 | A|49998|0042477DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0007 | A|49998|0036752DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0008 | A|49998|0052601DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0009 | A|49998|0038926DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0010 | A|49998|0038916DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0011 | A|49998|0049740DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0012 | A|49998|0032950DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0013 | A|49998|0027549DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0014 | A|49998|0044189DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0015 | A|49998|0005209DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0016 | A|49998|0011895DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0017 | A|49998|0008180DRAWING DATA=ERB553-1003-MF03450 |96169| A| |D|0018 | A|49998|0018601DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0001 | A|49998|0056831DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0002 | A|49998|0036178DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0003 | A|49998|0067084DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0004 | A|49998|0020551DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0005 | A|49998|0041619DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0006 | A|49998|0036523DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0007 | A|49998|0039219DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0008 | A|49998|0037181DRAWING DATA=ERB553-2200-MF00140 |96169| A| |D|0009 | A|49998|0017405DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0001 | A|49998|0050954DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0002 | A|49998|0026818DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0003 | A|49998|0070451DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0004 | A|49998|0037409DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0005 | A|49998|0024070DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0006 | A|49998|0027789DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0007 | A|49998|0055237DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0008 | A|49998|0040651DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0009 | A|49998|0041691DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0010 | A|49998|0039731DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0011 | A|49998|0039657DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0012 | A|49998|0033413DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0013 | A|49998|0007370DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0014 | A|49998|0019031DRAWING DATA=ERB553-2200-MF00181 |96169| A| |D|0015 | A|49998|0014926DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0001 | A|49998|0033997DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0001.A | A|49998|0045157DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0002 | A|49998|0021918DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0003 | A|49998|0023584DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0004 | A|49998|0020593DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0005 | A|49998|0045293DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0006 | A|49998|0042351DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0007 | A|49998|0035542DRAWING DATA=ERB553-2200-MF01530 |96169| A| |D|0008 | A|49998|0016157DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0001 | A|49998|0031704DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0001.A | A|49998|0043765DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0002 | A|49998|0016566DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0003 | A|49998|0020977DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0004 | A|49998|0015831DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0004.A | A|49998|0011033DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0005 | A|49998|0069238DRAWING DATA=ERB553-2200-MF03425 |96169| A| |D|0006 | A|49998|0015814DRAWING DATA=ERB553-2200-3G00008 |96169| A| |D|0001 | A|49998|0029799DRAWING DATA=ERB553-2200-3G00008 |96169| A| |D|0002 | A|49998|0030924DRAWING DATA=ERB553-2200-3G00008 |96169| A| |D|0003 | A|49998|0007940DRAWING DATA=ERB553-2200-3G00008 |96169| A| |D|0004 | A|49998|0015367DRAWING DATA=ERB553-2200-3G00008 |96169| A| |D|0005 | A|49998|0013292DRAWING DATA=MF04590 |53711| A|ER |D|0001 | A|49998|0329046DRAWING DATA=5959311 |53711| C| |D|0001 | C|00026|0000000DRAWING DATA=5959311C5 |53711| A|ER |D|0001 | A|49998|0674623DRAWING DATA=6404016 |53711| B| |F|0001 | B|00026|0000000DRAWING DATA=6405227 |53711| B| |D|0001 | B|49998|0157242DRAWING DATA=6405227 |53711| B| |D|0002 | B|49998|0082937DRAWING DATA=6405227 |53711| B| |D|0002.A | B|49998|0065719DRAWING DATA=6405227 |53711| B| |D|0003 | B|49998|0091771DRAWING DATA=6405227 |53711| B| |D|0004 | B|49998|0096949DRAWING DATA=6405227 |53711| B| |D|0005 | B|49998|0089577DRAWING DATA=7409397 |03538| C| |D|0001 | C|49998|0062373DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | |DOCUMENT REF DATA=ASTM-B150 | | | |190401|A| | |DOCUMENT REF DATA=QQ-N-281 | | |D |851023|A|2 | |DOCUMENT REF DATA=QQ-N-286 | | |G |001207|A| | |DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | |DOCUMENT REF DATA=MIL-DTL-1222 | | |J |001208|A| | |DOCUMENT REF DATA=MIL-T-1368 | | |C |001212|A|4 | |DOCUMENT REF DATA=ASTM-E1417 | | | |160615|A| | |DOCUMENT REF DATA=ASTM-E1444 | | | |160601|A| | |DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | |DOCUMENT REF DATA=MIL-STD-2132 | | |D |080310|F| |01|DOCUMENT REF DATA=ASTM-D4066 | | | |130701|A| | |DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | |DOCUMENT REF DATA=ISO10012 | | | |030415|A| | |DOCUMENT REF DATA=MIL-T-16420 | | |K |880916|A|1 | |DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | |DOCUMENT REF DATA=QPL 25027 | | |17 |000207|A| | |DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A|1 | |DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | |DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | |DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01|DOCUMENT REF DATA=AIA/NAS NASM 25027 | | |1 |121221|A| | |DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | |DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | |DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | |3. REQUIREMENTS3.1 ;The ball joint must be in accordance with NAVSEA drawing 596-7409397 Assembly B and NAVSEA drawing 801-6405227 Assembly 91 less Find Nos. 16, 19, and 31, along with all Engineering Reports provided, except as amplified or modified herein.;3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise:Part - ;Retainer, Part Number 2; Ball, Part Number 3; Flange, Part Number 6; and Upper Body, Part Number 9 of drawing 7409397;Material - ;QQ-N-281 Class A Form 2 Condition Forged HTNSL (SR);Part - ;Grease Valve Body, Part Number 4 of drawing 7409397;Material - ;QQ-N-281 Class A Form 1 Cold Drawn (SR);Part - ;Flange, Part Number 11 of drawing 7409397;Material - ;QQ-N-281 Class A;Part - ;Tube, Part Number 10 of drawing 7409397;Material - ;MIL-T-1368 Class A;Part - ;Stud, Part Number 20 of drawing 7409397;Material - ;QQ-N-286 Cold drawn, annealed, and age hardened or hot finished, annealed and age hardened.;;NOTE: Reference to Note 47 on drawing must be disregarded for Stud, Part Number 20.;PART - ;Self-locking Hex Nut, Part Number 21 of drawing 7409397;MATERIAL - QQ-N-281, class A annealed (hot finished or cold drawn) or class B cold drawn.All material must be from the same class.SELF-LOCKING ELEMENT- ASTM-D4066, Group 01, Class 1, Grade 1Part - ;Tubing, Part Number 7 of drawing 7409397;Material - ;MIL-T-16420 Comp 70/30 CL-1650 TY-I GR-2;Part - ;Needle Valve, Find No. 30 of drawing 6405227;Material - ;ASTM-B150 Alloy C63200;3.3 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings is still required, but certifications are only required as listed below.Attribute - Certificate of Compliance for seamless tubing/pipeItem - ;Tubing, Part Number 7 and Tube, Part Number 10 of drawing 7409397;Performance - Material supplied must be in the seamless condition.Test - ;5x Visual Magnification Inspection (root layer);Item - ;Joint Numbers J2033, J2034, J2035, and J2038;Performance - ;T9074-AS-GIB-010/271;Acceptance - ;MIL-STD-2035;Test - ;Visual and Dye Penetrant Inspection (final layer);Item - ;Joint Numbers J2032, J2033, J2034, J2035, and J2038;Performance - ;T9074-AS-GIB-010/271;Acceptance - ;MIL-STD-2035;Test - Non-Destructive TestsItem - ;Weld Repair (as applicable);Performance - Per applicable fabrication specificationAcceptance - Per applicable fabrication specificationTest - ;Hydrostatic testing;Item - ;Each Assembly;Performance - ;Note 7018 of drawing 7409397;Acceptance - ;Note 7018 of drawing 7409397;Test - ;Dye Penetrant Inspection for Non-Magnetic Grades;Item - ;Self-Locking Hex Nut;Performance - T9074-AS-GIB-010/271 or ASTM-E1417/ASTM-E1444 (Method C solvent removal techniques must not be used on thread)Acceptance - ;NASM25027;Test - Quality Conformance TestsItem - Self-Locking NutsPerformance - ;NASM25027;Acceptance - ;NASM25027;Attribute - Certificate of CompletionItem - Self-Locking Nut Nonmetallic InsertPerformance - ;ASTM-D4066, Group 01, Class 1, Grade 1;Attribute - Certificate of ComplianceItem - Self-Locking NutsPerformance - This Certificate must state that self-locking nuts were manufactured by an approved source.
Approved sources are those listed on QPL-25027 for the appropriate fastener. This QPL may also be considered as approved sources for Heavy Hexself-locking nuts.Attribute - Annealing and Age HardeningItem - ;Stud;Performance - QQ-N-286Test - Ultrasonic Inspection on Starting MaterialItem - ;All Items requiring certification made from QQ-N-286 with a diameter or minimum distance between parallel surfaces of 4 inches or greater of the starting material, or when required by a drawing or specification invoked elsewhere in this contract;Performance - T9074-AS-GIB-010/271 or MIL-STD-2132, and QQ-N-286Acceptance - QQ-N-2863.4 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, thefollowing must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG / -0 PSIG.
For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 50 PSIG. For pressure tests above 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG.The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in thiscontract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes.
For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be +60 minutes / - 0 minutes.3.5 Confidential Hydrostatic Test Pressures - When test pressures are confidential, certification must reference ;803-6404016 Rev. B; and the item number to which the item was tested in lieu of the actual pressures.
Any drawing requirement to mark theworking pressure on the item does not apply and is strictly prohibited.3.6 Chemours Company (formerly DuPont) Teflon Coating 850G-204 and 852G-201. Use of Chemours Company (formerly DuPont) Teflon Coating 851N-204 and 852N-201 is acceptable until exhausted - Teflon coating of ball(s) must be in accordance with general note ;2. C.;of drawing ;803-5959311; .3.6.1 Naval Ordnance Systems Command OD 10362 First Revision dated 15 Aug 1961 is provided by Contract Support Library Reference Number CSD018 in ECDS at https://register.nslc.navy.mil/3.6.2 CSD099 provides guidance for acceptance/rejection of teflon-coated valve balls after valve assembly production testing.3.7 Ball Spherical Surface Waviness - Unless otherwise specified on drawing, all sealing area surfaces must have a spherical surface waviness which does not exceed 0.0005 inches of height per inch of spherical surface. Roughness and waviness ratings mustapply in a direction which yields the maximum rating, normally perpendicular to the lay.3.8 ;Surface waviness must be verified prior to Teflon coating.;3.9 Radiography is required on ;Joint Number J2032 and must be identified to the weld joint; .3.10 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test of QQ-N-286 must be performed by one of the following laboratories:Huntington Alloys, a Special Metals CompanyAttn: Bill Bolenr3200 Riverside DriveHuntington, WV 257059Phone: (304) 526-5889FAX: (304) 526-5973Metallurgical Consultants, Inc.Attn: W. M. Buehler4820 CarolinePO Box 88046Houston, TX 77288-0046Phone: (713) 526-6351FAX: (713) 526-2964Naval Surface Warfare Center, Carderock DivisionAttn: Eric Focht Code 6149500 Macarthur BlvdWest Bethesda, MD 20817-5700Phone: (301) 227-5032FAX: (301) 227-5576Teledyne AllvacAttn: Dr. W. D. Cao2020 Ashcraft Ave.Monroe, NC 28110Phone: (704) 289-4511FAX: (704) 289-4269Westmoreland Mechanical Testing and Research Inc.Attn: Andrew WisniewskiP.O.
Box 388Youngstown, PA 15696-0388Mannesmann RohrenwerkeMannesmann Forschungsinstitut (MFI)Attn: Dr. WeissPostfach 25116047251 DuisburgGermanyPhone: 011-49-0203-9993194FAX: 011-49-0203-9994415ThyssenKrupp VDM USA, Inc.Attn: D. C. Agarwal11210 Steeplecrest Drive, Suite 120Houston, TX 77065-4939Phone: (281) 955-66833.11 O-ring grooves and mating sealing surfaces must be inspected per the contractually invoked drawings or specifications. When the drawings or specifications do not provide specific defect criteria or state that no defects are allowed, the GeneralAcceptance Criteria (GAC) standard must be used for inspecting O-ring grooves and mating sealing surfaces only. Repairs to sealing surfaces and O-ring grooves with unacceptable defects may be accomplished within the limits of the size and tolerances providedin the applicable drawing.
Repairs thatwould exceed these limits require approval (including final dimensions). The data that is red lined (crossed out) is excluded from the GAC for this contract and is not to be used for acceptance or rejection criteria.The GAC document is identified as Contract Support Library Reference Number CSD008 at https://register.nslc.navy.mil/3.12 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, 0900-LP-001-7000 for brazing of piping and pressure vesselapplications, or S9074-AQ-GIB-010/248 for brazing of other applications. For all production and repair welding and brazing, personnel and procedures must be qualified under S9074-AQ-GIB-010/248 or 0900-LP-001-7000, as applicable.
Repair welding is notpermitted on ;QQ-N-286; . Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing.3.13 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document,including any/all invoked specifications and drawings.3.14 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format.Definitions are provided elsewhere in the Contract/Purchase Order.3.14.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer.
Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must providea copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance.3.14.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail.3.14.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies.
The Contractor must submit an EngineeringChange Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change.3.15 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection.3.16 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order.
The above documents are for GovernmentUse Only. Furtherapplication of the above documents is prohibited.prohibited.3.16.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. ^ QUALITY ASSURANCE REQUIREMENTS ^3.17 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results.
Certification must include the contractor's name, address and date, quantity inspected,identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptancecriteria used. Test procedure numbers may also be referenced on test reports.
Test reports on weldments must be identified to weld joint and layer.3.18 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate.3.18.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/nonacceptance by the Government representative to determine the system's effectiveness in meeting the qualityrequirements established in the Contract/Purchase Order.3.18.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, uponnotification, make his facilities available for audit by the contracting Officer or his authorized representative.3.18.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award ofany contract/purchase order.
Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement.3.18.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptlynotify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished.
If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency(DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately.3.18.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption.3.19 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved andrejected and the nature of corrective action taken as appropriate.
Inspection records must be traceable to the material inspected.3.19.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel must be madeavailable for operations of such devices and for verification of their accuracy and condition.3.19.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions providedby the Government representative.3.20 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility.
Such inspection can only be requested by or under authorizationof the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies beingpurchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant.
Uponreceipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearestDefense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately."3.20.1 The prime contractor's program must include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document.3.20.2 Each sub-tier supplier of material or services for items in Section 3 of this contract must be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or servicesspecified in the purchase order or contract.3.20.3 The prime contractor must ensure that the purchased product conformsto specified purchase requirements and this contract.
The type and extent of control applied to the supplier and the purchased product must be dependent upon the effect of thepurchased product on the end item represented by this contract.3.20.4 The prime contractor must evaluate the requirements of the contractand select suppliers based on their ability to supply the product in accordance with the prime contractor's requirements and the contract. Criteria for selection and evaluation must beestablished. Records of this effort must be available for review by the government.3.20.5 The prime contractor's supplier quality assurance program must provide for a review of purchase documents to assure applicable quality requirements are included or referenced in the documentation for compliance by the supplier.3.21 Government Furnished Material and/or Equipment (GFM/GFE) - When material or equipment is furnished by the Government, the Contractor must develop documented control procedures that require at least the following:3.21.1 Visual examination upon receipt to detect damage during transit.3.21.2 Inspection for completeness and proper type.3.21.3 Verification of material quality received.3.21.4 Periodic inspection and precautions to assure adequate storage conditions and to guard against damage from handling and deterioration during storage.3.21.5 Functional testing, either prior to or after installation, or both, as required by the Contract to determine satisfactory operation.3.21.6 Identification and protection from improper use or disposition.3.21.7 Reporting to the Government, any GFM or GFE property found damaged, malfunctioning, or otherwise unsuitable for use.
In the event of damage or malfunction during or after installation, the supplier must determine and record probable cause andnecessity for withholding the material from use.3.21.8 For GFE material, and as required by the terms of the bailment agreement, the supplier must establish procedures for adequate storage, maintenance, and inspection of bailed Government material. Records of all inspection and maintenance performed onbailed property must be maintained.3.21.9 Material returned to the contractor must be handled as GFM.3.22 Traceability and Certification Requirements - To assure that correct materials are installed in Level I/SUBSAFE systems, it is imperative that traceability be maintained from the material to the material certification test report and other requiredObjective Quality Evidence (OQE). The material certification report must completely and accurately reflect that the material supplied meets the specified requirements.
Materials requiring Traceability and Certification Data are identified within Paragraph 3,Section C of this contract/purchase order.3.22.1 The following provides the minimum requirements for maintaining material traceability and supplements the requirements specified in DI-MISC-81020 and elsewhere in the contract/purchase order. The Contractor must develop written procedures thatimplement the material control requirements stated herein and elsewhere in this Contract/Purchase Order.3.23 Material Traceability - The certification data report must be identified through a unique traceability number, heat-lot number, or heat-treat number, as applicable, which must also be marked on the material. This traceability marking on the material mustprovide direct traceability to the material's chemical composition and mechanical properties certification data.
For material produced by batch, continuous cast, or continuous pour processes, samples must be taken no less than once in every eight hours ofoperation for the purpose of validating proper chemical composition and mechanical properties. Traceability must be maintained through all process operations including any subcontracted operations, to the finished component.3.23.1 Material Marking for Traceability and Identification - The following are the minimum marking requirements. Additional/alternate marking requirements, if applicable, will be specified elsewhere in the contract/purchase order.
In addition to themarking requirements on applicable drawings and/or specifications, marking for traceability is required. All traceability markings must be permanently applied in accordance with MIL-STD-792 (except as specified below). An alternate marking method ispermissible provided it is an available option in the contractually invoked specification or drawing, except in instances where the material has been modified by this contract/purchase order and differs from that specified in the specification or drawing.3.23.2 Traceability markings for items with precision machined or plated surfaces, or material with suitable marking surface areas less than 3/8 inches square (either 3/8" x 3/8" or an area equal to 0.1406 inches square) must be applied to a durable tag andthe tag securely affixed to the material.3.23.3 Traceability markings must be maintained through assembly, and whenever possible must be visible after assembly.
For items where the marking is not visible after assembly, a durable tag must be securely attached to the assembly identifying the partnumber, piece number, traceability number, and the location of the permanent mark.3.23.4 Marking must be legible and must be located so as to not affect the form, fit, and function of the material. ; ;3.24 See CDRL DI-MISC-81020 (Chemical and Mechanical) - Material Certification - In addition to the certification data requirements specified in DI-MISC-81020, the following material certification requirements apply:3.24.1 Quantitative chemical and mechanical analysis of material traceable to traceability markings is required. Material certification test reports must include the class, form, condition, grade, type, finish, and/or composition, as applicable, of thematerial supplied.3.24.2 Re-identification and re-certification of material is required when the material is subjected to a process which alters it's properties. If the starting material or raw stock is processed in a manner that will not affect its chemical composition ormechanical properties, the original certifications for the chemical composition and mechanical properties, as required by the material specification, are acceptable.
Re-certification of the chemical or mechanical properties is required if a process is usedduring fabrication that alters the original properties of the material (e.g. alloying, heat treating, or forming). In these instances, the properties of the material must be re-determined and documented to reflect the altered condition. The altered materialmust be uniquely re-identified.
The properties thus determined and documented, are required for final certification and must conform to the material specification or the contract/purchase order requirements. When only the mechanical properties are altered,the original certification forchemical composition must be overstamped and annotated with the unique traceability material and at a minimum contain the information below.TRACEABILITY MARKING ________________________________________________ (marking on finished item)IS FABRICATED FROM RAW MATERIAL IDENTIFIED TOHEAT/LOT NUMBER ______________ AND HEAT TREAT NUMBER _____________________ (when applicable)_________________________________________ DATE _____________________ (name and signature of auth. co. rep.)3.24.3 Material certification data forwarded by the manufacturer must contain a signed certification that the report results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contractrequirements. Transcription of certification data is prohibited.3.24.4 Statements on material certification documents must be positive and unqualified.
Disclaimers such as "to the best of our knowledge" or "we believe the information contained herein is true" are not acceptable.3.24.5 If material is received without the required certification papers or with incorrect/missing data on the certification papers, the material will be rejected.3.25 Material Handling - The written material control process must include the following:3.25.1 All raw materials must have traceability markings (except as specified below).3.25.2 Stored raw materials requiring traceability must be segregated to preclude intermingling with materials not requiring traceability.3.25.3 When traceability markings will be removed by a manufacturing or fabrication process, the marking must be recorded prior to removal and be immediately restored upon completion of the process. If this cannot be done or is impractical, an appropriatematerial control procedure (such as a bag and tag, tagging, and/or tote box control) must be employed. The material control procedure must provide a method of positive control to preclude commingling of heats/lots or loss of traceability.
The traceabilitymarking must be reapplied upon completion of the final manufacturing process.3.25.4 Brazing or weld filler metals for strength welds forming or integral with pressure containing components or assemblies requiring traceability must be verified to be the correct material, and type or grade, as applicable, prior to consumption. At aminimum, material verification must consist of inspection of material test reports for conformance to specified requirements. Control of welding and brazing filler metals must be maintained to the point of consumption to assure use of the correct type andgrade.
Markings and traceability requirements do not apply to brazing and weld filler metals after consumption. It is the responsibility of the prime contractor to ensure conformance with the above requirements on welds performed by their subcontractors.3.25.5 Purchase orders for raw material must specify that the material be traceable to material certification test reports by traceability markings on the material and identified on the test reports. The certification data requirements contained inDI-MISC-81020 must be invoked by the prime contractor on all subcontractors supplying Level I material.3.25.6 The material control process must include requirements for the maintenance of traceability for items sent out for subcontracted operations.
If such operations would remove traceability markings, purchase or work orders must specify a method and markinglocation for remarking. The contractor must also ensure that subcontractor production controls are adequate to preclude commingling of materials during processing.3.26 Receiving inspection -3.26.1 Products and services produced by sub-tier suppliers for incorporation in the contract end item must be subject to inspection or audit at the time of receipt by the prime prior to further processing within the prime contractor's plant or shipment toanother location.3.26.2 Receiving Inspection must include as a minimum -Verification that the traceability marking on the material agrees with that on the certification test reports.Verification that certification test reports are legible and complete.Verification that the contents of the certification test reports are in compliance with the contractually invoked specifications and requirements.3.27 Discrepancy reporting -3.27.1 Nonconforming products from sub-tier suppliers must be identified and processed in accordance with the prime contractor's procedures for controlling nonconforming products. The prime contractor must report the receipt of any nonconforming products tothe responsible sub-tier supplier in accordance with established procedures.
Nonconforming material records must be maintained and available for review by the government Quality Assurance Representative (QAR).3.28 Final Inspection - The following inspections must be performed prior to Government inspection and acceptance.3.28.1 Material Sampling - Material must be inspected for form, fit, and function. Lot acceptance must be based on zero defects and lot rejection based on one defect. The sample size must be in accordance with the sampling plan(s) in the applicable militaryspecification or standard, federal specification or standard, or drawing to which the material was manufactured.
In the absence of such sampling plans, sampling inspection must be per ANSI/ASQ-Z1.4, general inspection level II (for sample size selection code),table IIA (for sample size).SMALL LOT SIZES - For lot sizes of fifty or less, the minimum sample size must be eight units. For lot sizes of eight or less, the sample size must be one hundred percent of the lot.3.28.2 The Manufacturer may elect to use Statistical Process Control (SPC) to assure product quality in lieu of the above attribute sampling plan, provided that the SPC methodology/system used provides acceptable products to the Government. However, theGovernment/Navy Receipt Inspection Activity may perform their acceptance inspection of the material using the attribute sampling plan outlined above.3.28.3 All data concerning material verification (chemical, mechanical or physical properties), traceability (material certifications to material marking), and nondestructive test (NDT) certifications for material must be 100% inspected.
The certificationtest reports must also be 100% inspected for completeness and legibility.3.28.4 All material requiring traceability must be 100% inspected for traceability marking and that the marking is legible.3.29 See CDRLs DI-MISC-80875 (welding procedures) and DI-MISC-80876 (weld procedure qualification data) - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. Inaddition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor.Note: These requirements do not apply to tack/spot welds.3.29.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair).3.29.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. Theapproval letter must reference the applicable welding procedure and qualification data report identification/number.
Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must besubmitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF.
The contractor must state the applicability of each weld procedure and qualification data submitted,citing the drawing number and pieces to be welded. (i.e. "WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC." WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ.")3.29.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendors responsibility to comply with the requirements of S9074-AQ-GIB-010/248, S9074-AR-GIB-010A/278, andthe contract.3.29.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; includingsize, depth, location, and a description of the proposed repair. Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld ProcedureSpecification (WPS) and Procedure Qualification Record (PQR) submittals are still required.
This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application.3.29.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 72 hour time limit may be modified upon mutualagreement between the vendor and DCMA.3.29.6 When drawings require hardfacing surface Iron or Nickel content not to exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submittedas part of the qualification data.3.29.7 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs clearly showing the fusion area) must be submitted for review and show consistent, minimized dilution.
All essentialelements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element.3.29.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278.3.29.9 When production or repair welding is required on titanium materials, the applicable fabrication plan, facilities procedure, training plan, and active welder qualification must also be submitted for review and approval.3.29.10 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicabledocumentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts.
The contractor's fabrication plan, facilities procedure, trainingplan, and active welder qualification must be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation must be submitted in a commercially available electronic format, such as Adobe Acrobat PDF.3.
The contractor must manufacture and deliver a ball joint in accordance with NAVSEA drawing 596-7409397 Assembly B and NAVSEA drawing 801-6405227 Assembly 91 less Find Nos. 16, 19, and 31, along with all Engineering Reports provided. The material is designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and requires quantitative chemical and mechanical analysis for specified parts, testing certifications, and a quality system in accordance with ISO-9001. The contractor must also submit various CDRLs including an Inspection and Test Plan, Certification Data for Special Emphasis Material, and Welding Procedures.
We post new food & catering opportunities in Pennsylvania as agencies publish them. Get them in one email — free, and unsubscribe whenever.
"17050-0788""MECHANICSBURG""PA""USA""P O BOX 2020""5450 CARLISLE PIKE""014949967-N0010424QFD59-DWG-6-21-24.pdf"4617122"file"".pdf""1""2024-06-21T21:24:36.052+00:00""c3e2a04b79f94ef1b62db42296da5929""private""0""controlled""9d91ba7d0a5b49c49a4aeb80c9b96fc6""1"3"0""014949967-N0010424QFD59-RPT-6-21-24.pdf"292953"file"".pdf""1""2024-06-21T21:24:36.052+00:00""203f56e8d6bc4fb4877e809c7c406327""private""0""controlled""a5382d04311040b6bd8ebd2dc27875a4""1"2"0""014949967-N0010424QFD59-CLASS-REQ-6-21-24.docx"14305"file"".docx""1""2024-06-21T21:24:36.052+00:00""cb4d80e9a9fb468e8fe6df5ec7a78d21""private""0""controlled""4010f886b355437892f80f8721092164""1"1"0""https://www.neco.navy.mil/biz_ops/840-v5soln.aspx?soln=N0010424QFD590005"0"link""1""2026-10-20T22:44:32.629+00:00""c906f571da0346139519fb4a9f152d6b""public""0""See Solicitation N0010424QFD590005""public""d0b076c9cc23422a8889470f64e3725a""0"5"0""https://www.neco.navy.mil/biz_ops/840-v5soln.aspx?soln=N0010424QFD590003"0"link""1""2026-01-21T08:44:58.894+00:00""f5bfe47f6c8542c6adb22f47e95135ca""public""0""See Solicitation N0010424QFD590003""public""f4d710c5b30e43778fd8192afc42228a""0"4"0""https://www.neco.navy.mil/biz_ops/840-v5soln.aspx?soln=N0010424QFD590002"0"link""1""2025-04-01T07:22:44.635+00:00""83e5059188e14984abc689a7ea1b06c4""public""0""See Solicitation N0010424QFD590002""public""b163c79dcc184fe8a4a7212d1ac6dacb""0"3"0""https://www.neco.navy.mil/biz_ops/840-v5soln.aspx?soln=N0010424QFD590001"0"link""1""2025-03-04T08:27:14.84+00:00""7dab85dd5782485886b64cf5bc68b9c7""public""0""See Solicitation N0010424QFD590001""public""e56da913efae48bd80533d27281b82b8""0"2"0""https://www.neco.navy.mil/biz_ops/840-v5soln.aspx?soln=N0010424QFD59"0"link""1""2024-06-20T08:09:28.05+00:00""7848984a61bb4f0294d1827d5436ff7d""public""0""See Solicitation N0010424QFD59""public""08b02cb632604c538c9bfcf3a2e9d5c6""0"1"0"Most Pennsylvania work asks for the two below, and the solicitation documents are where it’s stated. One prequalification covers both — on this bid and the next.
A surety’s written statement that it expects to bond you up to a stated amount, subject to final underwriting. It’s what an agency asks to see before they take your bid seriously.
Source: SAM.gov (notice 92227977c99c4723a6a286b9271aa4d5), retrieved via the SAM.gov Get Opportunities API. View the official posting, and always confirm requirements and deadlines with the issuing agency.