The 460th Civil Engineering Squadron requires a qualified contractor to handle a recovery project for three (3) 200-ton Daikin air-cooled chillers, specifically Model AWV014AFFNGGN00 located on Buckley SFB. Since their installation in 2018, these units have been running on beta software, so the primary task is to update them to the latest stable manufacturer release. In addition, the contractor shall calibrate the sensors, integrate the chillers with the existing Building Automation System, and specifically diagnose and repair a known compressor degradation issue on all three units. This isn't a standard recurring maintenance contract; it is a one-time corrective requirement designed to fix lingering issues from the original installation and get the units safely recommissioned. The service shall be completed within 30 days after receipt of award.
This requirement needs to be accomplished and fully certified under (Unified Facilities Criteria) UFC 3-410-01: Heating, Ventilating, and Air Conditioning Systems. A contractor possessing the software tools, licensing, and diagnostic equipment to flash the firmware and troubleshoot the compressor without voiding existing equipment warranties is required.
Please see the attached RFQ document which contains further details regarding this solicitation including the Statement of Work and included provisions/clauses.
The contractor shall provide fully qualified technicians and all specialized tools to inspect and recommission three (3) 200 Ton Air-Cooled Screw Chillers installed in 2018. Work includes updating all chiller software to the current version, calibrating sensors and actuators, adjusting settings to optimize performance with the existing building automation system, performing a complete annual inspection, diagnosing and rectifying Chiller 1 with known compressor degradation, performing operational and safety checks, and delivering a deficiency report. All work shall be performed in accordance with UFC 3-410-01 and manufacturer specifications.
"80011-9572""BUCKLEY AFB""CO""USA""CP 720 847 6437""510 S ASPEN ST RM 120D""Request for Quote - FA254326Q0025 - Daikin Chiller Servicing.pdf"1077022"file"".pdf""1""2026-08-07T22:34:25.35+00:00""33b3af992f7144acb910e1429c82e26f""public""0""public""8f7916263e34420db618b6abde2477a1""0"1"0"Source: SAM.gov (notice 4eed0f6629654164b46a09cd89f17669), retrieved via the SAM.gov Get Opportunities API. View the official posting , always confirm requirements and deadlines with the issuing agency.