Due to a recent fire in building 6418 at Moore Air Base, Texas, a wet fire suppression system is needed. Building 6418 was constructed in the early 1980s with no fire suppression initially. Contractor shall provide design/as-built drawings submittals and installation of a new retrofitted system. The system shall be a turnkey project encompassing everything needed to have a fully functioning fire suppression system.
Solicitation documents are posted below.
NOTE: For those wishing to attend the site visit, please send names of attendees to james.g.roloff@usda,gov. A valid drivers license or state ID is required.
Amendment 1 is posted below.
RFI: Does Building 6418 currently have an existing fire alarm panel/system that the sprinkler monitoring would tie into? If so, could you please provide the panel/system type, make/model, or any available details needed for a sprinkler monitoring quote? The fire panels are old and obsolete. They will be replaced at another time, but the new sprinkler system must be able to connect to a fire panel in the future. No monitoring is needed.
The sign-in sheet for the site visit is posted below.
Building drawings posted below.
RFIs and responses posted below.
Amendment 2 is posted below. It extends the closing date.
The contractor shall provide design/as-built drawings submittals and installation of a new retrofitted wet fire suppression system, including underground fire line, tap, PIV, above-ground backflow preventer with testing certification, riser room, and a turnkey automatic sprinkler system with canopy protection and sprinkler heads centered in ceiling tiles using flex drops. The contractor must remove and dispose of all construction materials and debris off base, provide a one-year warranty on all labor and equipment, and comply with all applicable codes, environmental regulations, and NFPA standards.
"US""55401""MINNEAPOLIS""MN""USA""USDA APHIS""SUITE 410""12639526Q0210-0002.pdf"200160"file"".pdf""1""2026-08-05T20:13:18.163+00:00""5c9e37a937be44219852e8220abfb584""public""0""public""28bc82849eb54be5a8682ad2e938236b""0"8"0""RFIs and Responses.docx"17189"file"".docx""1""2026-08-02T14:24:01.419+00:00""f0ccb0e8333f409bba9a83f53c6f524a""public""0""public""aec1591119a84a4387d78c1023a32511""0"7"0""MFFRF_Bldg 6418 drawings_06201984.pdf"93884375"file"".pdf""1""2026-07-28T15:05:59.945+00:00""e2b81839a7144c9e88a81bdecdee4e17""public""0""public""787f0c9583ea44829f13e8ba16945f2f""0"6"0""6418 Fire Suppression System Sign-In Sheet.pdf"476879"file"".pdf""1""2026-07-24T13:36:27.572+00:00""1a9aff63782744fea50cbdaea66d1043""public""0""public""a7df02b8f77547759bf3fad8f5b32b20""0"5"0""12639526Q0210-0001.pdf"200561"file"".pdf""1""2026-07-10T18:54:51.575+00:00""046b426f958649f287d3f533a6bec921""public""0""public""15c1d117f19e439abc23a06f0750bbba""0"4"0""Attachment 2_Federal Construction Wage Rates_Hidalgo County.txt"13428"file"".txt""1""2026-07-08T18:17:24.81+00:00""e6de64c67422481d8fccef96986021f7""public""0""public""afd8ac64f6d24510b13ede7b5386387b""0"3"0""Attachment 1_Statement of Work.docx"43463"file"".docx""1""2026-07-08T18:17:24.81+00:00""52ed53cb316c40e59b6472828db84f08""public""0""public""1744690ec955435882b60b46cd7db16d""0"2"0""12639526Q0210.docx"81993"file"".docx""1""2026-07-08T18:17:24.81+00:00""6103f54f38cf483ea766997d2f708d83""public""0""public""8ecbfa6aa10a475dbfe7755c15980b41""0"1"0"Source: SAM.gov (notice 0457a02bca9c48c18fb441d49fc4b7cb), retrieved via the SAM.gov Get Opportunities API. View the official posting , always confirm requirements and deadlines with the issuing agency.