Light RFP
Federal · SAM.gov · New York

UHR Laser Profilometry Equipment for 155mm M776 M284 cannon bore measurement

This opportunity closed on Jul 24, 2026. Browse current bids below.
Closed Jul 24, 2026·General ConstructionView official posting ↗
Issuing agency
Department of Defense
Method
Combined Synopsis/Solicitation
Category
NAICS 334519
PIN
W911S226U3751
Location
New York
Posted
Jul 17, 2026
Takeaways by LightRFP AI

Generate a quick AI overview of this bid, pulled from its details and the attached documents.

Description

1.0 DescriptionThis equipment is required to be used with YPG existing Video Bore Inspection System and Laser Bore Inspection System measurement equipment, providing ultra-high-resolution UHR non-contact laser profilometry measurement for 155mm M776 and M284A2 cannon gun tubes. These specifications are required to ensure compatibility.2.0 Deliverables2.1 Qty 1, 155mm Large Caliber Laser Profilometry Scanner Assembly, UHR2.2 Qty 1, 155mm Large Caliber Calibration Ring, UHR3.0 Specification, 155mm Large Caliber Laser Profilometry Scanner Assembly, UHR3.1 Compatibility: must be fully compatible with existing VBIS, LVDT, and LBIS equipment, and shall support 155mm bore sizes.3.2 Key Specifications3.2.1 Axial Scan Resolution: Adjustable, 0.25 mm or 0.01 inch minimum3.2.2 Rotary Scan Resolution: Adjustable, 0.1 mm or 0.004 inch minimum3.2.3 Sensor Resolution: 0.005 mm or 0.0002 inch3.2.4 Measurement Repeatability: 0.012 mm or 0.0002 inch3.2.5 Measurement Accuracy ? Bore: Better than �0.012 mm or �0.0005 inch 3.2.6 Laser Power: less than 5 mW3.2.7 Laser Power Classification: IEC Class 3R3.2.8 Laser Spot Size: 0.025 mm or 0.0005 inch3.2.9 Laser Measurement Range: 152.43 ?

160.05 mm or 6.001 ? 6.301 inch 3.2.10 Centering Device Range: 149.5 ? 163.6 mm or 5.89 ?

6.44 inch4.0 Specification, Large Caliber Laser Profilometry Scanner Assembly4.1 Compatibility: must be fully compatible with existing VBIS, LVDT, and LBIS equipment, and shall support 155mm bore sizes.4.2 Key Specifications:4.2.1 Configuration: 3-step ring, with each step diameter within the Laser Measurement Range of the corresponding bore size scanner assembly4.2.2 Step Calibration Uncertainty: each step measured to better than 0.00005 inch or 1.27 �m uncertainty4.2.3 Certification: NIST Traceable

Documents4
oppMgmtLink.xhtmlXHTML
index.xhtmlXHTML
PIEE_Solicitation_Module_Vendor_Access_Instructions.pdfPDF
Document 4Link

Contact

Name
David Le
Phone
(928) 328-7686
Address
NY 85365
Full source recordfrom SAM.gov
Type
Combined Synopsis/Solicitation
Title
UHR Laser Profilometry Equipment for 155mm M776 M284 cannon bore measurement
Active
Yes
Base Type
Combined Synopsis/Solicitation
Notice Id
f468cff3c5484736942c841c501be8a8
Naics Code
334519
Department
DEPARTMENT OF DEFENSE
Posted Date
Jul 17, 2026
Office Address
State
NY
Zipcode
13602-5220
Country Code
USA
Point Of Contact
Type
primary
Email
david.v.le.civ@army.mil
Phone
9283287686
Full Name
David Le
Description Text
1.0 DescriptionThis equipment is required to be used with YPG existing Video Bore Inspection System and Laser Bore Inspection System measurement equipment, providing ultra-high-resolution UHR non-contact laser profilometry measurement for 155mm M776 and M284A2 cannon gun tubes. These specifications are required to ensure compatibility.2.0 Deliverables2.1 Qty 1, 155mm Large Caliber Laser Profilometry Scanner Assembly, UHR2.2 Qty 1, 155mm Large Caliber Calibration Ring, UHR3.0 Specification, 155mm Large Caliber Laser Profilometry Scanner Assembly, UHR3.1 Compatibility: must be fully compatible with existing VBIS, LVDT, and LBIS equipment, and shall support 155mm bore sizes.3.2 Key Specifications3.2.1 Axial Scan Resolution: Adjustable, 0.25 mm or 0.01 inch minimum3.2.2 Rotary Scan Resolution: Adjustable, 0.1 mm or 0.004 inch minimum3.2.3 Sensor Resolution: 0.005 mm or 0.0002 inch3.2.4 Measurement Repeatability: 0.012 mm or 0.0002 inch3.2.5 Measurement Accuracy ? Bore: Better than �0.012 mm or �0.0005 inch 3.2.6 Laser Power: less than 5 mW3.2.7 Laser Power Classification: IEC Class 3R3.2.8 Laser Spot Size: 0.025 mm or 0.0005 inch3.2.9 Laser Measurement Range: 152.43 ? 160.05 mm or 6.001 ? 6.301 inch 3.2.10 Centering Device Range: 149.5 ? 163.6 mm or 5.89 ? 6.44 inch4.0 Specification, Large Caliber Laser Profilometry Scanner Assembly4.1 Compatibility: must be fully compatible with existing VBIS, LVDT, and LBIS equipment, and shall support 155mm bore sizes.4.2 Key Specifications:4.2.1 Configuration: 3-step ring, with each step diameter within the Laser Measurement Range of the corresponding bore size scanner assembly4.2.2 Step Calibration Uncertainty: each step measured to better than 0.00005 inch or 1.27 �m uncertainty4.2.3 Certification: NIST Traceable
Response Dead Line
Jul 24, 2026
Full Parent Path Name
DEPARTMENT OF DEFENSE.DEPARTMENT OF THE ARMY.AMC.ACC.MISSION & INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place Of Performance
Zip
85365
Street Address
US ARMY YUMA PROVING GROUNDYUMA, AZ 85365
Solicitation Number
W911S226U3751

Source: SAM.gov (notice f468cff3c5484736942c841c501be8a8), retrieved via the SAM.gov Get Opportunities API. View the official posting — always confirm requirements and deadlines with the issuing agency.