Reroute Power Supple at the Phoenix Rearing Facility

Due Aug 14, 2026·17 days left·ElectricalView official posting ↗
Issuing agency
Department of Agriculture
Method
Combined Synopsis/Solicitation
Category
Construction · NAICS 238210
PIN
12639526Q0224
Location
Phoenix, AZ
Posted
Jul 22, 2026
Takeaways by LightRFP AI
  • The USDA APHIS is soliciting a small business to reroute electrical conduits at the Phoenix Rearing Facility in Phoenix, AZ.
  • The work involves removing two 2-inch rigid conduits that create a tripping hazard and rerouting 240-volt 3-phase supply power and control wires overhead to a mixing blender.
  • The solicitation is a Combined Synopsis/Solicitation with a magnitude under $25,000, set aside 100% for small business.
  • A mandatory site visit is scheduled for July 23, 2026 at 10:00 AM at 3645 E. Chipman RD, Phoenix AZ 85040.
  • Questions are due by 12:00 PM Central Time on July 29, 2026, and offers are due by 12:00 PM Central Time on August 14, 2026, both via email to erick.plamann@usda.gov.
  • The contractor must begin performance within 10 calendar days after award and complete work within 120 calendar days.
  • Requirement: The contractor must hold a valid electrician license as implied by the requirement for 'a licensed electrician' to perform the work.
  • Requirement: Performance and payment bonds are required as indicated by 'YES' in the solicitation form for furnishing required performance and payment bonds.
  • Requirement: The offeror must acknowledge receipt of amendments to the solicitation.
  • Requirement: The contractor must comply with the wage determination attached to the solicitation (C04_Attachment 3 Wage Determination.pdf).

AI-generated, verify all details against the official documents.

Description

Reroute Power Supply

POC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov

a licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will

have to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do

have fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.

NAICS Code: 238210

This is being solicited 100% Small Business

Magnitude: Under $25,000

Site Visit

Date: 23 July 2026

Time: 10:00 AM

Location: 3645 E. Chipman RD, Phoenix AZ 85040

POC: Marvin Draper

POC Email: marvin.draper@usda.gov

All question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.

All offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/14/0226.

Documents5
12639526Q0224 A0001.pdfPDF
C04_Attachment 1 SOI v2.pdfPDF
C04_Attachment 2 SOW.docxDOCX
C04_12639526Q0224.pdfPDF
C04_Attachment 3 Wage Determination.pdfPDF

Contact

Name
Erick Plamann
Address
Phoenix, AZ 85040
Full source recordfrom SAM.gov
Type
Combined Synopsis/Solicitation
Title
Reroute Power Supple at the Phoenix Rearing Facility
Active
Yes
Base Type
Combined Synopsis/Solicitation
Notice Id
bbf95338c4544393a4f4d8a1bc7994ad
Naics Code
238210
Department
DEPARTMENT OF AGRICULTURE
Posted Date
Jul 22, 2026
Categorized By
llm
Point Of Contact
Type
primary
Email
erick.plamann@usda.gov
Full Name
Erick Plamann
Description Text
Reroute Power Supply POC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov a licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will have to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do have fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles. NAICS Code: 238210 This is being solicited 100% Small Business Magnitude: Under $25,000 Site Visit Date: 23 July 2026 Time: 10:00 AM Location: 3645 E. Chipman RD, Phoenix AZ 85040 POC: Marvin Draper POC Email: marvin.draper@usda.gov All question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226. All offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/14/0226.
Response Dead Line
Aug 14, 2026
Full Parent Path Name
DEPARTMENT OF AGRICULTURE.ANIMAL AND PLANT HEALTH INSPECTION SERVICE.IS GUATEMALA
Place Of Performance
Zip
85040
City
Code
55000
Name
Phoenix
State
Code
AZ
Name
Arizona
Country
Code
USA
Name
UNITED STATES
Solicitation Number
12639526Q0224

Source: SAM.gov (notice bbf95338c4544393a4f4d8a1bc7994ad), retrieved via the SAM.gov Get Opportunities API. View the official posting — always confirm requirements and deadlines with the issuing agency.