Takeaways by LightRFP AI
  • The U.S. Army Corps of Engineers, Pittsburgh District, requires concrete repair at the Intake Tower stairwell of Tionesta Creek Lake.
  • The deteriorated concrete area is approximately 8 feet high, 7 feet wide, and at least 8 inches deep at elevation 1116.5.
  • Work includes concrete sounding, demolition, grout injection, reinforcement installation, bonding agent, waterstop, and new concrete placement.
  • NAICS code is 237990 (Other Heavy and Civil Engineering Construction) with a $45 million small business size standard.
  • This procurement is a 100% Small Business Set-Aside.
  • Posted date is 2026-07-08 and due date is 2026-08-10.
  • Requirement: All offerors must be a small business under NAICS 237990 with size standard $45,000,000.00.

AI-generated, verify all details against the official documents.

Description

The U.S. Army Corps of Engineers, Pittsburgh District, requires repairs to a deteriorated section of concrete within the stairwell of the Intake Tower at Tionesta Creek Lake. The repair is necessary to restore watertightness, prevent inundation of interior spaces during high-water events, and maintain safe access for project personnel. The deteriorated section of concrete is located at elevation 1116.5 and encompasses an area approximately 8 feet high from elevation 1116.5, 7 feet wide from the right wall, and at least 8 inches deep, or until the contractor encounters sound concrete.

The contractor shall sound the concrete, mark the limits of demolition, and remove all unsound material. After demolition, a non-shrink, low-pressure injection grout shall be installed around the full perimeter of the existing concrete to reduce seepage from the gatewell into the stairwell. Reinforcement shall be installed, which includes horizontal, vertical, and bent-hook bars that are doweled and epoxied into the existing structure.

All reinforcement must maintain a minimum clear cover of three inches. A concrete bonding agent shall be applied to all existing surfaces. A hydrophilic waterstop shall be installed along all vertical and horizontal joints to minimize future leakage.

Formwork shall be set flush with the existing wall face, and new concrete shall be placed and vibrated to ensure full consolidation and a uniform finish. The North American Industrial Classification Code (NAICS) is 237990 ? Other Heavy and Civil Engineering Construction.

The Small Business Size Standard is $45,000,000.00. This procurement is a 100% Small Business Set-Aside. All interested and capable offerors are encouraged to submit a quote. Information regarding the U.S. Army Corps of Engineers process for settling requests for equitable adjustments and duration goals to achieve definitization of equitable adjustments for change orders under construction contracts can be found by going to https://www.usace.army.mil/Strategic-Partnerships/Partnering/mod/129895/details/443/ then scrolling down on right hand side of page by clicking on ?View FFP Contract Changes Playbook Here?.

Documents4
oppMgmtLink.xhtmlXHTML
index.xhtmlXHTML
PIEE_Solicitation_Module_Vendor_Access_Instructions.pdfPDF
Document 4Link

Contact

Name
Mario TAORMINA
Phone
(412) 395-7256
Address
PA 16353
Full source recordfrom SAM.gov
Type
Solicitation
Title
Tionesta Dam Control Tower Concrete Repair
Active
Yes
Base Type
Solicitation
Notice Id
840de15aabee4b8a8996a1664457abb5
Naics Code
237990
Department
DEPARTMENT OF DEFENSE
Posted Date
Jul 8, 2026
Categorized By
llm
Office Address
State
PA
Zipcode
15222-4198
Country Code
USA
Point Of Contact
Type
primary
Email
Mario.Taormina@usace.army.mil
Phone
4123957256
Full Name
Mario TAORMINA
Type
secondary
Email
Connie.L.Ferguson@usace.army.mil
Phone
4123957551
Full Name
Connie L. Ferguson
Description Text
The U.S. Army Corps of Engineers, Pittsburgh District, requires repairs to a deteriorated section of concrete within the stairwell of the Intake Tower at Tionesta Creek Lake. The repair is necessary to restore watertightness, prevent inundation of interior spaces during high-water events, and maintain safe access for project personnel. The deteriorated section of concrete is located at elevation 1116.5 and encompasses an area approximately 8 feet high from elevation 1116.5, 7 feet wide from the right wall, and at least 8 inches deep, or until the contractor encounters sound concrete. The contractor shall sound the concrete, mark the limits of demolition, and remove all unsound material. After demolition, a non-shrink, low-pressure injection grout shall be installed around the full perimeter of the existing concrete to reduce seepage from the gatewell into the stairwell. Reinforcement shall be installed, which includes horizontal, vertical, and bent-hook bars that are doweled and epoxied into the existing structure. All reinforcement must maintain a minimum clear cover of three inches. A concrete bonding agent shall be applied to all existing surfaces. A hydrophilic waterstop shall be installed along all vertical and horizontal joints to minimize future leakage. Formwork shall be set flush with the existing wall face, and new concrete shall be placed and vibrated to ensure full consolidation and a uniform finish. The North American Industrial Classification Code (NAICS) is 237990 ? Other Heavy and Civil Engineering Construction. The Small Business Size Standard is $45,000,000.00. This procurement is a 100% Small Business Set-Aside. All interested and capable offerors are encouraged to submit a quote. Information regarding the U.S. Army Corps of Engineers process for settling requests for equitable adjustments and duration goals to achieve definitization of equitable adjustments for change orders under construction contracts can be found by going to https://www.usace.army.mil/Strategic-Partnerships/Partnering/mod/129895/details/443/ then scrolling down on right hand side of page by clicking on ?View FFP Contract Changes Playbook Here?.
Response Dead Line
Aug 10, 2026
Full Parent Path Name
DEPARTMENT OF DEFENSE.DEPARTMENT OF THE ARMY.USACE.LRD.W072 ENDIST PITTSBURGH
Place Of Performance
Zip
16353
Street Address
477 Spillway Road, Tionesta, Pennsylvania
Solicitation Number
W911WN26QA043